Background: It is currently unknown if outcomes after transcatheter aortic valve replacement (TAVR) differ according to the prosthetic valve deployed in patients with bicuspid aortic valves (BAV).

Objectives: This study evaluated valve-specific outcomes post-TAVR in patients with BAV.

Methods: Literature search was performed using the Cochrane databases, PubMed, ClinicalTrials, SCOPUS and EMBASE databases from inception until July 2018. We computed risk ratios and their 95% confidence intervals for all outcomes of interest. For each outcome, the data were pooled using a multivariate random-effects meta-analysis including multiple treatment as well as direct and indirect comparisons.

Results: Ten studies enrolling a total of 1547 BAV patients undergoing TAVR using 6 different prosthetic valve types were analyzed. There were no significant differences in 30-day all-cause mortality, life-threatening bleeding and device success among the diverse prosthetic valve types implanted. However, 2nd generation balloon-expandable valves had consistently lower risk of moderate-to-severe prosthetic valve regurgitation.

Conclusion: In patients with BAV, there were no significant differences in 30-day all-cause mortality after TAVR among the various prosthetic valve types.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carrev.2020.01.011DOI Listing

Publication Analysis

Top Keywords

prosthetic valve
20
valve types
12
patients undergoing
8
transcatheter aortic
8
valve
8
aortic valve
8
valve replacement
8
bicuspid aortic
8
aortic valves
8
tavr prosthetic
8

Similar Publications

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

Background: Surgical aortic valve replacement (SAVR) is the commonly used approach for aortic valve replacement (AVR) in patients with aortic stenosis at low or intermediate surgical risk. However, transcatheter aortic valve replacement (TAVR) has emerged as an alternative to SAVR for AVR. This meta-analysis aims to assess the comparative efficacy and safety of TAVR versus SAVR in low-to-intermediate surgical risk patients by analyzing temporal trends in the outcomes of TAVR and SAVR at various follow-up intervals, providing a more detailed understanding.

View Article and Find Full Text PDF

The spleen plays a crucial role in filtering aging blood cells and defending against encapsulated microorganisms. While not essential for survival, splenic dysfunction can lead to severe complications, including organ failure, infection, and death. This case study examines a rare presentation of drug-induced splenic septic thrombophlebitis secondary to pancreatitis caused by an adverse reaction to ceftriaxone.

View Article and Find Full Text PDF

Aortic valve leaflet assessment to inform novel bioinspired materials: Understanding the impact of collagen fibres on the tissue's mechanical behaviour.

J Mech Behav Biomed Mater

December 2024

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, 2, Dublin, Ireland; Discipline of Mechanical, Manufacturing, and Biomedical Engineering, School of Engineering, Trinity College Dublin, 2, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Ireland. Electronic address:

Aortic stenosis is a prevalent disease that is treated with either mechanical or bioprosthetic valve replacement devices. However, these implants can experience problems with either functionality in the case of mechanical valves or long-term durability in the case of bioprosthetic valves. To enhance next generation prosthetic valves, such as biomimetic polymeric valves, an improved understanding of the native aortic valve leaflet structure and mechanical response is required to provide much needed benchmarks for future device development.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!