Background: This study was aimed at comparing the accuracy of impressions of a reference typodont (RT) reproducing a totally edentulous maxilla made with three impression materials: polysulfide, polyether, and polyvinyl-siloxane.

Methods: The RT was scanned using a desktop scanner, obtaining a reference scan. Ten impressions for each of the three tested materials were made using a mechanical device with a standardized and consistent modality. A laboratory scanner performed the digitization of each impression. We produced digital models by processing "in reverse" the scans of the physical impressions using a dedicated software, obtaining three groups (n = 10), respectively. The groups were titled: "polysulfide," "polyvinyl-siloxane," and "polyether." The scans in .stl format were imported into Geomagic Control X and then compared to RT to evaluate the accuracy of each scan by calculating trueness and precision in µm. Recorded data were subjected to descriptive statistics.

Results: Trueness (arithmetic proximity) values (95%CI) were: polysulfide = 249.9 (121.3-378.5), polyvinyl-siloxane = 216.8 (123.1-310.6), polyether = 291.1 (219.9-362.3). Precision values (95% CI) were: polysulfide = 261.9 (108.8-415), polyvinyl-siloxane = 209.4 (111.9-306.8), polyether = 283 (227.9-338.1). Statistically significant differences were not detected between the means of the experimental groups, both for trueness and precision.

Conclusions: The accuracy of the scans obtained from polyvinyl-siloxane, polysulfide, and polyether impressions can be considered comparable in a fully edentulous maxilla.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7040790PMC
http://dx.doi.org/10.3390/ma13030515DOI Listing

Publication Analysis

Top Keywords

edentulous maxilla
12
three impression
8
impression materials
8
totally edentulous
8
polysulfide polyether
8
accuracy
4
accuracy three
4
materials totally
4
maxilla vitro/in
4
vitro/in silico
4

Similar Publications

Objective: This study aimed at investigating implant survival rate and marginal bone loss (MBL) around extra-short implants. The impact of the loading protocol and of the use of an intermediate abutment was also evaluated, to explore possible differences in terms of the outcome measures.

Materials And Methods: Patients with single or multiple mandibular or maxillary posterior edentulism rehabilitated using extra-short 5-6 mm long implants were included.

View Article and Find Full Text PDF

Background: The mechanical properties of framework materials significantly influence stress distribution and the long-term success of implant-supported prostheses. Although titanium, cobalt-chromium, zirconia, and polyether ether ketone (PEEK) are widely used, their biomechanical performance under dynamic loading conditions remains insufficiently investigated. This study aimed to evaluate the biomechanical behavior of four framework materials with different Young's modulus using dynamic finite element stress analysis.

View Article and Find Full Text PDF

Sandblasting and acid etching are common procedures used to treat implant surfaces, enhancing osseointegration and improving clinical success rates. This clinical study aimed to evaluate the long-term outcomes of sandblasted and acid-etched implants. A total of 303 implants were placed in 114 partially and totally edentulous patients using a two-stage surgical technique and an early loading protocol (6-8 weeks).

View Article and Find Full Text PDF

Dental implants are essential for the prosthetic rehabilitation of edentulous patients, requiring adequate bone volume and density for osseointegration and load support. The posterior region of the maxilla, commonly deficient in bone quality and quantity, represents a clinical challenge. This case series reports an analysis involving 69 dental implants in the atrophic maxilla of nine patients.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the clinical performance (degree of trueness) of a novel scan body "tooth-modified Scan body" (TMSB)& conventional scan body (CSB) in implant-supported full arch screw retained cases.

Methods: Seven edentulous arches (two maxillae, five mandibles) in 6 patients were rehabilitated with monolithic zirconia screw-retained implant prostheses supported by 4 (n = 1) and 5 implants (n = 6) for a total amount of 34 implants. Implant locations were scanned by intra-oral scanner (IOS) using two types of scan bodies, conventional scan bodies (CSB) in group (1) and tooth-modified scan bodies (TMSB) in group (2).

View Article and Find Full Text PDF