Objective: To identify and evaluate dose errors on medication orders that bypassed pharmacist verification in a pediatric emergency department (PED).

Methods: Descriptive, retrospective study about dose errors in an academic PED over 1 year. A report of automatically verified orders (those that bypassed pharmacist verification) was obtained from the electronic medical record. Potential medication dose errors were defined as those greater than 20% above or below standard dose ranges by age or weight. A retrospective chart review was performed for all identified dose errors. For orders deemed erroneous, additional metrics collected included order time of day and day of week and provider training level.

Results: A total of 46,185 medication orders were placed; 32,928 (71%) bypassed pharmacist review. Altogether, 676 orders (2%) were outside standard dose ranges. Ondansetron represented 569 of the 676 orders; most were doses rounded down to 4 mg and technically qualifying as underdoses, but were attributed to practice variance and not further analyzed. The number of orders deemed potentially erroneous was 107: most were wrong dose (75 overdose and 21 underdose), 5 were wrong patient, and 6 were wrong formulation. Ibuprofen, benzodiazepine, and corticosteroid orders had the most errors. No errors resulted in identifiable harm to the patient: 49 were near misses, and 47 reached the patient with no evident harm.

Conclusions: The overall number of dose errors in autoverified orders was low. Certain medications or ordering modalities may be targeted to enhance patient safety and satisfaction.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PEC.0000000000002024DOI Listing

Publication Analysis

Top Keywords

dose errors
24
bypassed pharmacist
16
medication orders
12
orders bypassed
12
orders
10
dose
9
medication dose
8
errors
8
pediatric emergency
8
emergency department
8

Similar Publications

Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.

Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.

View Article and Find Full Text PDF

Introduction: The Society for Pediatric Anesthesia Quality and Safety Committee developed the Pediatric Regional Anesthesia Time-Out Checklist, consisting of 14 safety items intended to be reviewed by an anesthesia team prior to a regional anesthetic. Primarily, we hypothesized that use of this Checklist would increase the number of safety items performed compared with no checklist, evaluating the usefulness of this tool. Secondarily, we hypothesized that, after checklist training, subjects would show better clinical judgment by electing to perform a regional anesthetic in scenarios in which no programmed error existed and electing to not perform a regional anesthetic in scenarios in which a programmed error did exist.

View Article and Find Full Text PDF

/: Inhaler devices have been developed for the effective delivery of inhaled medications used in the treatment of pulmonary diseases. However, differing operating procedures across the devices can lead to user errors and reduce treatment efficacy, especially when patients use multiple devices simultaneously. To address this, we developed a novel dry powder inhaler (DPI), combining fluticasone propionate (FP), salmeterol xinafoate (SX), and tiotropium bromide (TB) into a single device designed for bioequivalent delivery compared to existing commercial products in an animal model.

View Article and Find Full Text PDF

Background: Total-body (TB) Positron Emission Tomography (PET) is one of the most promising medical diagnostics modalities, opening new perspectives for personalized medicine, low-dose imaging, multi-organ dynamic imaging or kinetic modeling. The high sensitivity provided by total-body technology can be advantageous for novel tomography methods like positronium imaging, demanding the registration of triple coincidences. Currently, state-of-the-art PET scanners use inorganic scintillators.

View Article and Find Full Text PDF

Background: Computed tomography scans are widely used in everyday medical practice due to speed, image reliability, and detectability of a wide range of pathologies. Each scan exposes the patient to a radiation dose, and performing a fast estimation of the effective dose (E) is an important step for radiological safety. The aim of this work is to estimate E from patient and CT acquisition parameters in the absence of a dose-tracking software exploiting machine learning.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!