A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effectiveness of Phantom Stimulation in Shifting the Pitch Percept in Cochlear Implant Users. | LitMetric

Objectives: Phantom electrode stimulation was developed for cochlear implant (CI) systems to provide a lower pitch percept by stimulating more apical regions of the cochlea, without inserting the electrode array deeper into the cochlea. Phantom stimulation involves simultaneously stimulating a primary and a compensating electrode with opposite polarity, thereby shifting the electrical field toward the apex and eliciting a lower pitch percept. The current study compared the effect sizes (in shifts of place of excitation) of multiple phantom configurations by matching the perceived pitch with phantom stimulation to that perceived with monopolar stimulation. Additionally, the effects of electrode location, type of electrode array, and stimulus level on the perceived pitch were investigated.

Design: Fifteen adult advanced bionics CI users participated in this study, which included four experiments to eventually measure the shifts in place of excitation with five different phantom configurations. The proportions of current delivered to the compensating electrode, expressed as σ, were 0.5, 0.6, 0.7, and 0.8 for the symmetrical biphasic pulses (SBC0.5, SBC0.6, SBC0.7, and SBC0.8) and 0.75 for the pseudomonophasic pulse shape (PSA0.75). A pitch discrimination experiment was first completed to determine which basal and apical electrode contacts should be used for the subsequent experiments. An extensive loudness balancing experiment followed where both the threshold level (T-level) and most comfortable level (M-level) were determined to enable testing at multiple levels of the dynamic range. A pitch matching experiment was then performed to estimate the shift in place of excitation at the chosen electrode contacts. These rough shifts were then used in the subsequent experiment, where the shifts in place of excitation were determined more accurately.

Results: Reliable data were obtained from 20 electrode contacts. The average shifts were 0.39, 0.53, 0.64, 0.76, and 0.53 electrode contacts toward the apex for SBC0.5, SBC0.6, SBC0.7, SBC0.8, and PSA0.75, respectively. When only the best configurations per electrode contact were included, the average shift in place of excitation was 0.92 electrode contacts (range: 0.25 to 2.0). While PSA0.75 leads to equal results as the SBC configurations in the apex, it did not result in a significant shift at the base. The shift in place of excitation was significantly larger at the apex and with lateral wall electrode contacts. The stimulus level did not affect the shift.

Conclusions: Phantom stimulation results in significant shifts in place of excitation, especially at the apical part of the electrode array. The phantom configuration that leads to the largest shift in place of excitation differs between subjects. Therefore, the settings of the phantom electrode should be individualized so that the phantom stimulation is optimized for each CI user. The real added value to the sound quality needs to be established in a take-home trial.

Download full-text PDF

Source
http://dx.doi.org/10.1097/AUD.0000000000000845DOI Listing

Publication Analysis

Top Keywords

place excitation
32
electrode contacts
24
phantom stimulation
20
shifts place
16
shift place
16
electrode
15
pitch percept
12
electrode array
12
phantom
9
cochlear implant
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!