A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Novel Dual-Hormone Insulin-and-Pramlintide Artificial Pancreas for Type 1 Diabetes: A Randomized Controlled Crossover Trial. | LitMetric

Objective: The rapid insulin-alone artificial pancreas improves glycemia in type 1 diabetes but daytime control remains suboptimal. We propose two novel dual-hormone artificial pancreas systems.

Research Design And Methods: We conducted a randomized crossover trial comparing a rapid insulin-alone artificial pancreas with rapid insulin-and-pramlintide and with regular insulin-and-pramlintide artificial pancreas systems in adults with type 1 diabetes. Participants were assigned to the interventions in random order during three 24-h inpatient visits. Each visit was preceded by an outpatient hormonal open-loop run-in period of 10-14 days. The dual-hormone artificial pancreas delivered pramlintide in a basal-bolus manner, using a novel dosing algorithm, with a fixed ratio relative to insulin. The primary outcome was time in the range 3.9-10.0 mmol/L.

Results: Compared with the rapid insulin-alone artificial pancreas system, the rapid insulin-and-pramlintide system increased the time in range from 74% (SD 18%) to 84% (13%) ( = 0.0014), whereas the regular insulin-and-pramlintide system did not change the time in range (69% [19%]; = 0.22). The increased time in range with the rapid insulin-and-pramlintide system was due to improved daytime control (daytime time in range increased from 63% [23%] to 78% [16%], = 0.0004). There were 11 (1 per 2.5 days) hypoglycemic events (<3.3 mmol/L with symptoms or <3.0 mmol/L irrespective of symptoms) with the rapid insulin-alone system, compared with 12 (1 per 2.3 days) and 18 (1 per 1.4 days) with the rapid and regular insulin-and-pramlintide systems, respectively. Gastrointestinal symptoms were reported after 0% (0 of 112) of meals with the rapid insulin-alone system, compared with 6% (6 of 108) and 11% (11 of 104) with the rapid and regular insulin-and-pramlintide systems, respectively; none of the symptoms were severe.

Conclusions: A novel rapid insulin-and-pramlintide artificial pancreas improves glucose control compared with a rapid insulin-alone artificial pancreas (ClinicalTrials.gov number NCT02814123).

Download full-text PDF

Source
http://dx.doi.org/10.2337/dc19-1922DOI Listing

Publication Analysis

Top Keywords

artificial pancreas
28
time range
20
type diabetes
12
rapid insulin-alone
12
insulin-alone artificial
12
rapid insulin-and-pramlintide
12
insulin-and-pramlintide system
12
novel dual-hormone
8
insulin-and-pramlintide artificial
8
crossover trial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!