A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of Fecal Occult Blood Testing as a Diagnostic Tool for Clinical Indications: A Systematic Review and Meta-Analysis. | LitMetric

Introduction: Fecal occult blood tests (FOBTs) are validated only for colorectal cancer (CRC) screening, but are commonly used as a diagnostic test in other clinical settings. We performed a systematic review to assess performance characteristics of FOBT as a diagnostic test for clinical indications.

Methods: Bibliographic databases were searched to identify studies in adult patients with a specific gastrointestinal symptom or condition who underwent FOBT and a reference test and provided data on diagnoses. Our primary end point was sensitivity. Risk of bias was assessed with the QUADAS-2 tool.

Results: Twenty-two studies met the inclusion criteria: 12 in iron deficiency anemia (IDA) (5 fecal immunochemical (FIT) and 7 guaiac based), 8 in ulcerative colitis (FIT), and 2 in acute diarrhea (guaiac based). Only 2 studies had low risk of bias on all domains of the QUADAS-2. On meta-analysis, FOBT had a sensitivity of 0.58 (95% confidence interval [CI] 0.53-0.63) and a specificity of 0.84 (95% CI 0.75-0.89) in predicting presumptive causes of IDA at endoscopy, with comparable results for guaiac-based tests and FIT. Sensitivity was higher for CRC (0.83) than non-CRC lesions (0.54). FIT had a sensitivity of 0.72 (95% CI 0.57-0.84) and a specificity of 0.80 (95% CI 0.67-0.89) in predicting endoscopic activity in UC. Sensitivities of FOBT for positive stool culture in acute diarrhea were 0.38 and 0.87.

Discussion: Sensitivity of FOBT is poor for IDA: 42% of patients with identifiable causes of IDA had false-negative FOBT. Our results did not show acceptable performance characteristics for FOBT to guide decisions regarding endoscopic evaluation and do not support its use in IDA.

Download full-text PDF

Source
http://dx.doi.org/10.14309/ajg.0000000000000495DOI Listing

Publication Analysis

Top Keywords

fecal occult
8
occult blood
8
systematic review
8
diagnostic test
8
test clinical
8
performance characteristics
8
characteristics fobt
8
risk bias
8
guaiac based
8
acute diarrhea
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!