AI Article Synopsis

  • The study aimed to assess the elastic recovery of irreversible hydrocolloid impression materials by measuring undercut depths and testing different thicknesses of spacer for custom tray fabrication.
  • It involved surveying and 3D printing dental casts with various undercut categories, followed by making custom trays with different spacer thicknesses and analyzing the elastic recovery using calipers.
  • Results showed no significant difference in measurements between the casts made from 3D prints and poured casts, leading to the recommendation of applying an additional 3mm of spacer for effective impression taking in removable partial denture construction.

Article Abstract

Objectives: To evaluate the elastic recovery of a typical irreversible hydrocolloid impression material in terms of the amount of undercut identified and additional thickness of spacer provided before custom tray fabrication.

Methods: This study surveyed the undercut depths of the teeth surfaces and lingual sulci of one hundred partially dentate mandibular dental casts which were subsequently scanned and the data exported as STL files. A typical cast from each undercut category (0.5mm, 1mm, 1.5mm, 2mm, 2.5mm, 3mm, 4mm, 5mm) was 3D printed. Three custom trays were constructed with spacer thicknesses representing 20%, 30% and 50% compression against the wall of the custom trays on removal, impressions recorded, and casts fabricated in dental stone. Measurements for elastic recovery of irreversible hydrocolloid were done using an internal caliper and a digital caliper. All measurements were done by the principal investigator. Non-parametric analyses were used for comparisons of the undercut values between the 3D printed and poured casts to determine the amount of elastic recovery of the irreversible hydrocolloid impression material.

Results: There was no statistically significant difference in measurements between the original 3D printed casts and the poured casts, irrespective of percentage compression (p 0.05).

Conclusions: In removable partial denture construction, casts should be blocked out parallel to the path of insertion and then an additional 3mm of spacer applied as a standard technique before custom tray fabrication to ensure elastic recovery of the irreversible hydrocolloid impression.

Clinical Implications: In severe undercut situations, accurate impressions can be taken using irreversible hydrocolloid by blocking out all undercut surfaces on the teeth and lingual sulci before adapting additional three-millimetre wax spacer on casts when constructing custom trays thereby ensuring accurate and reliable impressions for removable prosthesis construction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6965733PMC
http://dx.doi.org/10.1016/j.heliyon.2019.e03143DOI Listing

Publication Analysis

Top Keywords

irreversible hydrocolloid
24
elastic recovery
16
hydrocolloid impression
12
custom trays
12
recovery irreversible
12
undercut depths
8
casts
8
casts poured
8
custom tray
8
lingual sulci
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!