Background: Discectomy and fusion is considered the "gold standard" treatment for clinical manifestations of degenerative disc disease in the cervical spine. However, clinical and biomechanical studies suggest that fusion may lead to adjacent-segment disease. Cervical disc arthroplasty preserves the motion at the operated level and may potentially decrease the occurrence of adjacent segment degeneration. The purpose of this study was to investigate the effect of disc generation, fusion, and disc replacement on the motion, disc stresses, and facet forces on the cervical spine by using the finite element method.

Methods: A validated, intact, 3-dimensional finite element model of the cervical spine (C2-T1) was modified to simulate single-level (C5-C6) and 2-level (C5-C7) degeneration. The single-level degenerative model was modified to simulate both single-level fusion and arthroplasty (total disc replacement [TDR]) using the Bryan and Prestige LP discs. The 2-level degenerative model was modified to simulate a 2-level fusion, 2-level arthroplasty, and single-level disc replacement adjacent to single-level fusion (hybrid). The intact models were loaded by applying a moment of ±2 Nm in flexion-extension, lateral bending, and axial rotation. The motion in each direction was noted and the other modified models were loaded by increasing the moment until the primary C2-T1 motion matched that of the intact (healthy) C2-T1 motion.

Results: Both Bryan and Prestige discs preserved motion at the implanted level and maintained normal motions at the adjacent nonoperative levels. A fusion resulted in a decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR (both) preserved motion adjacent to the fusion, thus reducing the demand on the other levels. The disc stresses followed the same trends as motion. Facet forces increased considerably at the index level following a TDR.

Conclusion: The Bryan and Prestige LP TDRs both preserved motion at the implanted level and maintained normal motion and disc stresses at the adjacent levels. The motion patterns of the spine with a TDR more closely resembled that of the intact spine than those of the degenerative or fused models.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6962001PMC
http://dx.doi.org/10.14444/6066DOI Listing

Publication Analysis

Top Keywords

cervical spine
16
disc replacement
16
disc
12
finite element
12
motion
12
disc stresses
12
modified simulate
12
bryan prestige
12
preserved motion
12
fusion
9

Similar Publications

Delayed presentation of severe cervical myelopathy two years post-motorcycle accident: a case report.

N Z Med J

January 2025

Active Living and Rehabilitation: Aotearoa New Zealand, Health and Rehabilitation Research Institute, Faculty of Health and Environmental Sciences, Auckland University of Technology, Auckland, New Zealand.

View Article and Find Full Text PDF

Introduction: Pain from the cervical facet joints, either due to degenerative conditions or due to whiplash-related trauma, is very common in the general population. Here, we provide an overview of the literature on the diagnosis and treatment of cervical facet-related pain with special emphasis on interventional treatment techniques.

Methods: A literature search on the diagnosis and treatment of cervical facet joint pain and whiplash-associated disorders (WAD) was performed using PubMed, Cochrane, and Embase databases.

View Article and Find Full Text PDF

The scope of existing annular closure device (ACD) studies examining long-term follow-up data is limited. There is a paucity of studies that report and analyze recent outcomes data following ACD use. We sought to summarize the available long-term follow-up data on postoperative outcomes of the Barricaid (Intrinsic Therapeutics) ACD.

View Article and Find Full Text PDF

The Canadian Association of Radiologists (CAR) Cancer Expert Panel is made up of physicians from the disciplines of radiology, medical oncology, surgical oncology, radiation oncology, family medicine/general practitioner oncology, a patient advisor, and an epidemiologist/guideline methodologist. The Expert Panel developed a list of 29 clinical/diagnostic scenarios, of which 16 pointed to other CAR guidelines. A rapid scoping review was undertaken to identify systematically produced referral guidelines that provide recommendations for one or more of the remaining 13 scenarios.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the outcomes of minimally invasive PCF using an interfacet joint fusion cage.

Methods: The inclusion criteria consisted of patients who underwent a PCF using an interfacet device (Cavux, Providence Medical Technology Inc.) at a single institution and were at least 6 months postoperative.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!