A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bubble versus other continuous positive airway pressure forms: a systematic review and meta-analysis. | LitMetric

Background: Use of bubble continuous positive airway pressure (CPAP) has generated considerable interest in neonatal care, but its comparative effectiveness compared with other forms of CPAP, especially in developed countries, remains unclear.

Objective: To systematically review and meta-analyse short-term clinical outcomes among preterm infants treated with bubble CPAP vs all other forms of CPAP.

Methods: Prospective experimental studies published from 1995 onward until October 2018 comparing bubble versus other CPAP forms in preterm neonates <37 weeks' gestational age were included after a systematic review of multiple databases using pre-specified search criteria.

Results: A total of 978 articles were identified, of which 19 articles were included in meta-analyses. Of these, 5 had a high risk of bias, 8 had unclear risk and 6 had low risk. The risk of the primary outcome (CPAP failure within 7 days) was lower with bubble CPAP (0.75; 95% CI 0.57 to 0.98; 12 studies, 1194 subjects, I=21%). Among secondary outcomes, only nasal injury was higher with use of bubble CPAP (risk ratio (RR) 2.04, 95% CI 1.33 to 3.14; 9 studies, 983 subjects; I=42%) whereas no differences in mortality (RR 0.82, 95% CI 0.47 to 1.92; 9 studies, 1212 subjects, I=20%) or bronchopulmonary dysplasia (BPD) (RR 0.8, 95% CI 0.53 to 1.21; 8 studies, 816 subjects, I=0%) were noted.

Conclusion: Bubble CPAP may lead to lower incidence of CPAP failure compared with other CPAP forms. However, it does not appear to translate to improvement in mortality or BPD and potential for nasal injury warrants close monitoring during clinical application.

Trial Registration Number: CRD42019120411.

Download full-text PDF

Source
http://dx.doi.org/10.1136/archdischild-2019-318165DOI Listing

Publication Analysis

Top Keywords

bubble versus
8
continuous positive
8
positive airway
8
airway pressure
8
cpap forms
8
bubble
4
versus continuous
4
forms
4
pressure forms
4
forms systematic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!