Intravenous chemotherapy plus abdominal locoregional hyperthermia is explored as a noninvasive alternative to hyperthermic intraperitoneal chemotherapy (HIPEC) in treatment of peritoneal carcinomatosis (PC). First clinical results demonstrate feasibility, but survival data show mixed results and for pancreatic and gastric origin results are not better than expected for chemotherapy alone. In this study, computer simulations are performed to compare the effectiveness of peritoneal heating for five different locoregional heating systems. Simulations of peritoneal heating were performed for a phantom and two pancreatic cancer patients, using the Thermotron RF8, the AMC-4/ALBA-4D system, the BSD Sigma-60 and Sigma-Eye system, and the AMC-8 system. Specific absorption rate (SAR) distributions were optimized and evaluated. Next, to provide an indication of possible enhancement factors, the corresponding temperature distributions and thermal enhancement ratio (TER) of oxaliplatin were estimated. Both phantom and patient simulations showed a relatively poor SAR coverage for the Thermotron RF8, a fairly good coverage for the AMC-4/ALBA-4D, Sigma-60, and Sigma-Eye systems, and the best and most homogeneous coverage for the AMC-8 system. In at least 50% of the peritoneum, 35-45 W/kg was predicted. Thermal simulations confirmed these favorable peritoneal heating properties of the AMC-8 system and TER values of ∼1.4-1.5 were predicted in at least 50% of the peritoneum. Locoregional peritoneal heating with the AMC-8 system yields more favorable heating patterns compared to other clinically used locoregional heating devices. Therefore, results of this study may promote the use of the AMC-8 system for locoregional hyperthermia in future multidisciplinary studies for treatment of PC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/02656736.2019.1710270 | DOI Listing |
Appl Clin Inform
October 2024
Department of Psychiatry, University of Rochester Medical Center, Rochester, New York, United States.
Background: Choice architecture refers to the design of decision environments, which can influence decision-making in health care. Nudges are subtle adjustments in these environments that guide decisions toward desired outcomes. For example, computerized provider order entry within electronic health records (EHRs) recommends frequencies for interventions such as nursing assessments and medication administrations, but these can link to around-the-clock schedules without clinical necessity.
View Article and Find Full Text PDFInt J Hyperthermia
October 2020
Department of Radiation Oncology, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
Intravenous chemotherapy plus abdominal locoregional hyperthermia is explored as a noninvasive alternative to hyperthermic intraperitoneal chemotherapy (HIPEC) in treatment of peritoneal carcinomatosis (PC). First clinical results demonstrate feasibility, but survival data show mixed results and for pancreatic and gastric origin results are not better than expected for chemotherapy alone. In this study, computer simulations are performed to compare the effectiveness of peritoneal heating for five different locoregional heating systems.
View Article and Find Full Text PDFInt J Hyperthermia
November 2018
a Department of Radiation Oncology , Academic Medical Center, University of Amsterdam, Amsterdam , The Netherlands.
Background: The effectiveness of hyperthermia is strongly dependent on the achieved tumour temperatures. Phased-array systems allow flexible power steering to realise good tumour heating while avoiding excessive heating in normal tissue, but the limited quantitative accuracy of pre-treatment planning complicates realising optimal tumour heating. On-line hyperthermia treatment planning could help to improve the heating quality.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
November 2017
Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Background: Adequate tumor temperatures during hyperthermia are essential for good clinical response, but excessive heating of normal tissue should be avoided. This makes locoregional heating using phased array systems technically challenging. Online application of hyperthermia treatment planning could help to improve the heating quality.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
March 2014
Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia.
Methods And Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!