Optimal in situ electromechanical sensing of molecular species.

J Chem Phys

Biophysics Group, Microsystems and Nanotechnology Division, Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA.

Published: January 2020

We investigate protocols for optimal molecular detection with electromechanical nanoscale sensors under ambient conditions. Our models are representative of suspended graphene nanoribbons, which due to their piezoelectric and electronic properties provide responsive and versatile sensors. In particular, we analytically account for the corrections in the electronic transmission function and signal-to-noise ratio originating in environmental perturbations, such as thermal fluctuations and solvation effects. We also investigate the role of the sampling time in the current statistics. As a result, we formulate a protocol for optimal sensing based on the modulation of the Fermi level at a fixed bias and provide approximate forms for the current, linear susceptibility, and current fluctuations. We show how the algebraic tails in the thermally broadened transmission function affect the behavior of the signal-to-noise ratio and optimal sensing. These results provide further insights into the operation of graphene deflectometers and other techniques for electromechanical sensing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7159976PMC
http://dx.doi.org/10.1063/1.5132581DOI Listing

Publication Analysis

Top Keywords

electromechanical sensing
8
transmission function
8
signal-to-noise ratio
8
optimal sensing
8
optimal
4
optimal situ
4
situ electromechanical
4
sensing
4
sensing molecular
4
molecular species
4

Similar Publications

In every heartbeat, cardiac muscle cells perform excitation-Ca signaling-contraction (EC) coupling to pump blood against the vascular resistance. Cardiomyocytes can sense the mechanical load and activate mechano-chemo-transduction (MCT) mechanism, which provides feedback regulation of EC coupling. MCT feedback is important for the heart to upregulate contraction in response to increased load to maintain cardiac output.

View Article and Find Full Text PDF

A novel wearable device integrating ECG and PCG for cardiac health monitoring.

Microsyst Nanoeng

January 2025

Key Laboratory of Instrumentation Science and Dynamic Measurement Ministry of Education, North University of China, 030051, Taiyuan, China.

The alarming prevalence and mortality rates associated with cardiovascular diseases have emphasized the urgency for innovative detection solutions. Traditional methods, often costly, bulky, and prone to subjectivity, fall short of meeting the need for daily monitoring. Digital and portable wearable monitoring devices have emerged as a promising research frontier.

View Article and Find Full Text PDF

Bioinspired Smart Triboelectric Soft Pneumatic Actuator-Enabled Hand Rehabilitation Robot.

Adv Mater

January 2025

Division of Intelligent and Biomechanical Systems, State Key Laboratory of Tribology in Advanced Equipment, Department of Mechanical Engineering, Tsinghua University, Haidian, Beijing, 100084, China.

Quantitative assessment for post-stroke spasticity remains a significant challenge due to the encountered variable resistance during passive stretching, which can lead to the widely used modified Ashworth scale (MAS) for spasticity assessment depending heavily on rehabilitation physicians. To address these challenges, a high-force-output triboelectric soft pneumatic actuator (TENG-SPA) inspired by a lobster tail is developed. The bioinspired TENG-SPA can generate approximately 20 N at 0.

View Article and Find Full Text PDF

Cardiovascular diseases account for ~40% of global deaths annually. This situation has revealed the urgent need for the investigation and development of corresponding drugs for pathogenesis due to the complexity of research methods and detection techniques. An in vitro cardiomyocyte model is commonly used for cardiac drug screening and disease modeling since it can respond to microphysiological environmental variations through mechanoelectric feedback.

View Article and Find Full Text PDF

Background: To investigate the optimization of leadless pacemaker placement and to assess its impact on heart synchronization and tricuspid regurgitation.

Results: A clinical trial was conducted involving 53 patients who underwent leadless pacemaker implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine and Hangzhou First People's Hospital between March 2022 and February 2023. Implantation site localization was determined using the 18-segment method under RAO 30° imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!