Introduction And Objectives: Atrioventricular block (AVB) in the presence of bradycardic drugs (BD) can be reversible, and pacemaker implantation is controversial. Our objective was to analyze the pacemaker implantation rate in the mid-term, after BD suspension, and to identify predictive factors.

Methods: We performed a cohort study that included patients attending the emergency department with high-grade AVB in the context of BD. We studied the persistence of AVB after BD discontinuation, recurrence in patients with AVB resolution, and the predictive variables associated with pacemaker requirement at 3 years.

Results: Of 127 patients included (age, 79 [71-83] years), BAV resolved in 60 (47.2%); among these patients, recurrence occurred during the 24-month median follow-up in 40 (66.6%). Pacemaker implantation was required in 107 patients (84.3%), despite BD discontinuation. On multivariable analysis, the variables associated with pacemaker need at 3 years were heart rate <35 bpm (OR, 8.12; 95%CI, 1.82-36.17), symptoms other than syncope (OR, 4.09; 95%CI, 1.18-14.13), and wide QRS (OR, 5.65; 95%CI, 1.77-18.04). Concomitant antiarrhythmic treatment was associated with AVB resolution (OR, 0.12; 95%CI, 0.02-0.66).

Conclusions: More than 80% of patients with AVB secondary to BD require pacemaker implantation despite drug discontinuation. Predictive variables were wide QRS, heart rate <35 bpm, and clinical presentation other than syncope.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rec.2019.09.028DOI Listing

Publication Analysis

Top Keywords

pacemaker implantation
12
atrioventricular block
8
bradycardic drugs
8
pacemaker requirement
8
variables associated
8
associated pacemaker
8
patients
6
pacemaker
6
block patients
4
patients undergoing
4

Similar Publications

Since the first transcatheter aortic valve replacement (TAVR) was performed in China in 2010, TAVR has developed rapidly. However, the temporal trends in the 1-year prognosis after TAVR in China have not been described. This study enrolled patients treated at a high-volume Chinese TAVR center, West China Hospital, between 2015 and 2022, to analyze and characterize the temporal trends in 1-year outcomes.

View Article and Find Full Text PDF

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully.

View Article and Find Full Text PDF

Background: The rate of permanent pacemaker implantation after tricuspid valve (TV) operation is thought to be high, with some studies quoting rates of 20% to 30%. We identified the rate of pacemaker implantation after TV operation at a high-volume regional reference center to better characterize the contemporary risk of pacemaker.

Methods: All adult patients without preexisting pacemakers undergoing TV operation from 2011 to 2022 were included.

View Article and Find Full Text PDF

Introduction: In patients with symptomatic, refractory atrial fibrillation the ablate and pace (A&P) strategy (pacemaker implantation followed by atrio-ventricular junction ablation (AVJA)) is superior to medical therapy in improving quality of life and prognosis. Despite its well-proven benefits, this invasive therapeutic option is still underutilized in clinical practice. The choice of pacing modality (right ventricular pacing, biventricular pacing, BVP, or conduction system pacing, CSP) is crucial and can have significant clinical implications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!