Objective: To evaluate clinical outcomes from a postmarket registry of the Zenith Spiral-Z abdominal aortic aneurysm iliac leg graft with a continuous, spiral nitinol stent that was designed for improved conformability, kink, and migration resistance.
Methods: This prospective, multicenter registry was designed to evaluate physician-reported outcomes of the Spiral-Z leg graft in up to 600 patients who underwent endovascular repair of abdominal aortic or aortoiliac aneurysms at up to 30 investigative sites in the United States and Canada. Study outcomes were focused on iliac limb occlusion, limb-related reintervention, limb-related endoleak, component separation, and device integrity. Short-term data were collected during an interval of 1 to 6 months, with longer term data collected at 12 months.
Results: Between March 2012 and March 2015, 599 patients (mean age 74 ± 8 years; 87% male; 26% with aortoiliac aneurysm) were treated, with Spiral-Z iliac leg grafts placed in 564 left iliac arteries and 559 right iliac arteries. The mean iliac inner diameters (both left and right) were 9 ± 3 mm; moderate/severe occlusive disease, calcification, and vessel tortuosity were present in 14%, 25%, and 36% and 15%, 25%, and 34% of the left and right iliac arteries, respectively. Iliac artery adjunctive procedures (iliac artery angioplasty and/or stent placement) were performed intraoperatively in 112 patients (19%; bilateral in 52 patients). Mortality within 30 days was 1.7% (10/599); cumulative mortality at 1 year was 6.2% (37/599). There were no aortic ruptures and only one open conversion (0.2%). Limb occlusions occurred in 11 of 599 patients (2%; 3 within 30 days and 8 after 30 days, all unilateral, none had received procedural iliac artery adjuncts at implantation); of these, 7 patients underwent reinterventions. Other limb-related reinterventions were performed on eight patients for nonocclusive kink, compression, or thrombus (six within 30 days and three after 30 days). In total, 13 patients (2%) underwent 15 limb-related reinterventions (7 for occlusions and 8 for nonocclusive causes). In one patient, a distal type I endoleak and device migration (>10 mm) involving a right iliac leg was noted at the 12-month follow-up visit. No other limb-related endoleak, migration, component separation, or stent fracture was reported during a mean follow-up of 11 ± 6 months.
Conclusions: The Spiral-Z leg graft demonstrated excellent patency and required infrequent limb-related reinterventions in routine clinical care in a postmarket registry.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvs.2019.10.078 | DOI Listing |
J Surg Case Rep
January 2025
Vascular Surgery Department, Bonifatius Hospital, Wilhelmstraße 13, 49808 Lingen, Germany.
We document a case of a 75-year-old patient with a history of hypercholesterolemia and hypertension, who underwent endovascular aortic repair (EVAR) for an infrarenal abdominal aortic aneurysm (AAA) with common iliac artery ectasia. Despite an initially successful procedure, the patient experienced recurrent episodes of acute limb ischemia in his right leg. Subsequent imaging revealed thrombus formation distal to the stent graft, constituting a potential source of embolization, which warranted a reevaluation of the treatment strategy.
View Article and Find Full Text PDFInt J Surg Case Rep
January 2025
Department of Vascular Surgery, Inselspital, University Hospital, University of Bern, 3010 Bern, Switzerland.
Introduction And Importance: Internal iliac artery aneurysms repair represents a life-threatening condition due to their anatomical position and the risk of rupture. Iliac branch devices are strongly recommended for anatomically suitable patients, but limited alternatives exist when their use is unsuitable. The use of custom-made fenestrated endografts is well documented in other aortic territories, however, their application for the treatment of internal iliac artery aneurysm remains limited.
View Article and Find Full Text PDFNeurospine
December 2024
Department of Neurosurgery, Chosun University Hospital, Gwangju, Korea.
This case report and video demonstrate the technique of full-endoscopic J-shaped transforaminal L5 exiting nerve decompression in Bertolotti syndrome. Bertolotti syndrome, characterized by a congenital lumbosacral transitional vertebra, often results in mechanical lower back pain and nerve root compression. A 69-year-old male presented with progressive radiating pain in the right leg and tingling in the L5 dermatome.
View Article and Find Full Text PDFInt J Surg Case Rep
January 2025
Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), Marudhar Industrial Area, 2nd phase, M.I.A. 1st phase, Basni, Jodhpur, Rajasthan 342005, India.
Introduction: Benign cartilage tumours with malignant transformation are reported very few. Aiming to report a secondary chondrosarcoma in proximal tibia after chondromyxoid fibroma: a rare entity with limited experience of management.
Case Presentation: we present a challenging case of secondary chondrosarcoma of proximal tibia in surgically managed chondromyxoid fibroma.
Simultaneous pancreas-kidney (SPK) transplantation is a recognized treatment for patients with insulin-dependent diabetes and advanced chronic kidney disease or end-stage renal disease (ESRD), offering significant survival benefits. However, it is associated with a higher risk of venous thrombosis, which can jeopardize the survival of the pancreaticoduodenal graft. This case report describes a patient with type 2 diabetes, hypertension, and ESRD who developed acute, occlusive deep vein thrombosis (DVT) involving the right common femoral, profunda femoral, and greater saphenous veins on postoperative day 1 (POD1) following a deceased donor SPK transplant, despite systemic prophylactic anticoagulation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!