Background: The bispectral index (BIS) has been evaluated as an indicator of central nervous system (CNS) depression in horses during general anaesthesia. The spectral entropy is another electroencephalographic device and it has not been evaluated yet in horses.

Objectives: To determine if spectral entropy can assess anaesthetic depth during the different phases of anaesthesia, define the value of state and response entropy during surgical plane of anaesthesia and compare them with BIS.

Study Design: Clinical, prospective, non-blinded observational study.

Methods: Thirty-five horses ASA I or II undergoing scheduled surgical procedure were used. BIS and electromyography (EMG) with a BIS monitor and state and response entropy with a spectral entropy monitor were recorded at baseline after receiving 5 µg/kg bwt i.v. of medetomidine (sedation period), during the anaesthetic maintenance with isoflurane and medetomidine (intraoperative period) and once the trachea was extubated (recovery period). A general linear model for repeated measurements was employed. Correlation and agreement between methods were also assessed. Data are presented as mean ± SD.

Results: State entropy, response entropy and EMG showed significant differences according to the anaesthetic period (P < .001). There was no significant difference in BIS between baseline and sedation period, but there were differences between the remainder of the periods (P < .001). BIS (53.4 ± 11.2) was significantly higher (P < .001) than response entropy (35.1 ± 7.1) and state entropy (27.4 ± 4.8) during surgical plane of anaesthesia. The ICC between BIS and response entropy was 0.56 and between BIS and state entropy was 0.43, without agreement between them.

Main Limitations: The need to shave the skin in contact with the sensors and the difficulty in taking measurements during recovery period.

Conclusions: Spectral entropy can be used to detect the different periods of an anaesthetic protocol, with the lowest values during the intraoperative period. A low correlation and no concordance were observed between both methods.

Download full-text PDF

Source
http://dx.doi.org/10.1111/evj.13234DOI Listing

Publication Analysis

Top Keywords

spectral entropy
16
response entropy
12
entropy
8
isoflurane medetomidine
8
general anaesthesia
8
state response
8
comparison bispectral
4
spectral
4
bispectral spectral
4
entropy isoflurane
4

Similar Publications

Purpose: Anti-N-methyl-D-aspartate receptor (NMDAR) encephalitis is an autoimmune reaction involving Immunoglobulin G antibodies against GluN1 subunit of NMDAR. Absence of biomarkers for early diagnosis and prognosis poses a challenge. Several small case-control studies have emphasized the prospect of quantitative EEG measurements.

View Article and Find Full Text PDF

Support for the efficient coding account of visual discomfort.

Vis Neurosci

December 2024

Department of Psychology to Division of Psychology, University of Stirling, Stirling, UK.

Sparse coding theories suggest that the visual brain is optimized to encode natural visual stimuli to minimize metabolic cost. It is thought that images that do not have the same statistical properties as natural images are unable to be coded efficiently and result in visual discomfort. Conversely, artworks are thought to be even more efficiently processed compared to natural images and so are esthetically pleasing.

View Article and Find Full Text PDF

High-harmonic generation (HHG) is a nonlinear process in which a material sample is irradiated by intense laser pulses, causing the emission of high harmonics of incident light. HHG has historically been explained by theories employing a classical electromagnetic field, successfully capturing its spectral and temporal characteristics. However, recent research indicates that quantum-optical effects naturally exist or can be artificially induced in HHG, such as entanglement between emitted harmonics.

View Article and Find Full Text PDF

Global synchronization of functional corticomuscular coupling under precise grip tasks using multichannel EEG and EMG signals.

Cogn Neurodyn

December 2024

Key Laboratory of Measurement Technology and Instrumentation of Hebei Province, Institute of Electric Engineering, Yanshan University, Qinhuangdao, Hebei China.

Functional corticomuscular coupling (FCMC), a phenomenon describing the information interaction between the cortex and muscles, plays an important role in assessing hand movements. However, related studies mainly focused on specific actions by one-to-one mapping between the brain and muscles, ignoring the global synchronization across the motor system. Little research has been done on the FCMC difference between the brain and different muscle groups in terms of precise grip tasks.

View Article and Find Full Text PDF

Parametrization of the dying brain: A case report from ICU bed-side EEG monitoring.

Neuroimage

December 2024

Department of Anesthesiology and Intensive Care Medicine, Technical University of Munich, School of Medicine and Health, 81675 Munich, Germany.

Background: Cortical high-frequency activation immediately before death has been reported, raising questions about an enhanced conscious state at this critical time. Here, we analyzed an electroencephalogram (EEG) from a comatose patient during the dying process with a standard bedside monitor and spectral parameterization techniques.

Methods: We report neurophysiologic features of a dying patient without major cortical injury.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!