Stability Analysis of Arteries Under Torsion.

J Biomech Eng

Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel.

Published: June 2020

Vascular tortuosity may impede blood flow, occlude the lumen, and ultimately lead to ischemia or even infarction. Mechanical loads like blood pressure, axial force, and also torsion are key factors participating in this complex mechanobiological process. The available studies on arterial torsion instability followed computational or experimental approaches, yet single available theoretical study had modeled the artery as isotropic linear elastic. This paper aim is to validate a theoretical model of arterial torsion instability against experimental data. The artery is modeled as a single-layered, nonlinear, hyperelastic, anisotropic solid, with parameters calibrated from experiment. Linear bifurcation analysis is then performed to predict experimentally measured stability margins. Uncertainties in geometrical parameters and in measured mechanical response were considered. Also, the type of rate (incremental) boundary conditions (RBCs) impact on the results was examined (e.g., dead load, fluid pressure). The predicted critical torque and twist angle followed the experimentally measured trends. The closest prediction errors in the critical torque and twist rate were 22% and 67%, respectively. Using the different RBCs incurred differences of up to 50% difference within the model predictions. The present results suggest that the model may require further improvements. However, it offers an approach that can be used to predict allowable twist levels in surgical procedures (like anastomosis and grafting) and in the design of stents for arteries subjected to high torsion levels (like the femoropopliteal arteries). It may also be instructive in understanding biomechanical processes like arterial tortuosity, kinking, and coiling.

Download full-text PDF

Source
http://dx.doi.org/10.1115/1.4046051DOI Listing

Publication Analysis

Top Keywords

arterial torsion
8
torsion instability
8
experimentally measured
8
critical torque
8
torque twist
8
torsion
5
stability analysis
4
analysis arteries
4
arteries torsion
4
torsion vascular
4

Similar Publications

Medical image-based diagnostic techniques have become increasingly common in the clinic. Estimating fractional flow reserve in coronary stenoses from medical image data is among the most prominent examples. The modeling techniques used in these clinical tools require rigorous experimental validation yet there is currently no standardized, public toolset to help assess model credibility.

View Article and Find Full Text PDF

Background: Given the lack of models for carotid artery dissections (CAD), we aim to investigate effects of beta-aminopropionitrile (BAPN) combined with physical damage on the arterial walls of rats, and to establish a high-incidence and low-mortality CAD model.

Methods: Sixteen SPF SD rats (3-week-old) were divided into two groups. Group B was given 0.

View Article and Find Full Text PDF

Can surface landmarks help us identify the gibson interval during surgical hip dislocation: a study of 617 hips.

Arch Orthop Trauma Surg

December 2024

Department of Orthopedic Surgery and Traumatology, HFR Cantonal Hospital, University of Fribourg, Fribourg, Switzerland.

Introduction: The Gibson approach, used in hip-preserving surgery, is intermuscular and develops the space anteriorly to the gluteus maximus. Reliable anatomical landmarks for the development of this interval do not exist, but the interval is marked by perforating vessels (PV) of the inferior gluteal artery. The aim of this study was to provide reference values for the relationship between palpable anatomical landmarks on the femur/pelvis and the anterior border of the gluteus maximus using CT scans of the proximal femur.

View Article and Find Full Text PDF

The testicular artery is the vessel that provides oxygen-rich blood to the testes. It is also involved in many more processes that play important roles in spermatogenesis such as thermoregulation. As the vessel has a number of anatomical variants, it may be often responsible for difficulties and complications during abdominopelvic surgical procedures.

View Article and Find Full Text PDF

Intrauterine Testicular Torsion: Two Prenatally Diagnosed Cases and Review of the Literature.

J Clin Ultrasound

December 2024

Department of Obstetrics and Neonatology, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), AUSL Reggio Emilia, Reggio Emilia, Italy.

The third-trimester ultrasound diagnosis in two fetuses with isolated testicular torsion is described. Pregnancy courses were uneventful and routine second-trimester scans had shown no structural anomalies. Antenatal ultrasound performed at 32 + 3 and 33 + 0 weeks' gestation showed signs consistent with the diagnosis of isolated left spermatic cord torsion in both cases (absent flow across the testicular artery, hyperechogenic small rounded mass in the hemiscrotum representing the twisted testes, and hydrocele).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!