Background And Objectives: The objective of this study was to evaluate the long-term clinical outcomes and the incidence of permanent pacemaker implantation after catheter ablation in patients with of atrial fibrillation (AF) and sinus node dysfunction (SND).

Methods: Among 3,068 total consecutive patients who underwent AF catheter ablation (AFCA), this study included 222 (9.5%; men 53.2%, 63.7±9.2 years of age, 81.5% paroxysmal AF) with underlying SND and a regular rhythm follow-up. We analyzed the rhythm outcomes, changes in the mean heart rate or heart rate variability, and permanent pacemaker implantation rate.

Results: During 47.5±28.8 months of follow-up, 25 (11.3%) patients received pacemaker implantations due to symptomatic SND. More than half (56.0%, 14/25) underwent a pacemaker implantation within 3 months of the AFCA, and the annual pacemaker implantation rate was 2.0% afterwards. Both the early (68.0% vs. 31.0%, p<0.001) and clinical AF recurrence (68.0% vs. 32.5%, p=0.001) rates and continuous antiarrhythmic drug use after 3 months (44.0% vs. 24.4%, p=0.036) were significantly higher in patients requiring pacemaker implantations than those that did not. An anterior linear ablation (odds ratio [OR], 9.37 [3.03-28.9]; p<0.001) and the E/Em (OR, 1.15 [1.02-1.28]; p=0.018) were independently associated with permanent pacemaker implantations after AFCA in patients with AF and SND.

Conclusions: After AFCA in patients with AF and SND, 1 of 9 patients needed a pacemaker implantation and half needed implantations within 3 months. The AF recurrence rate was significantly higher in those who required pacemaker implantations after the AFCA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7067613PMC
http://dx.doi.org/10.4070/kcj.2019.0268DOI Listing

Publication Analysis

Top Keywords

pacemaker implantation
16
permanent pacemaker
12
catheter ablation
12
pacemaker implantations
8
ablation patients
8
patients atrial
8
atrial fibrillation
8
sinus node
8
node dysfunction
8
heart rate
8

Similar Publications

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

We present the case of a 64-year-old man who, during the implantation of an active-fixation leadless pacemaker (LP, Aveir VR, Abbott, USA), underwent several external defibrillation shocks up to 240 Joules, due to symptomatic sustained supraventricular tachycardia at 160 bpm. The shocks, delivered both before and after the screwing of the device in the low interventricular septum, did not cause any technical damage to the device, and no complications were observed. The device was then deployed successfully.

View Article and Find Full Text PDF

Background: The rate of permanent pacemaker implantation after tricuspid valve (TV) operation is thought to be high, with some studies quoting rates of 20% to 30%. We identified the rate of pacemaker implantation after TV operation at a high-volume regional reference center to better characterize the contemporary risk of pacemaker.

Methods: All adult patients without preexisting pacemakers undergoing TV operation from 2011 to 2022 were included.

View Article and Find Full Text PDF

Introduction: In patients with symptomatic, refractory atrial fibrillation the ablate and pace (A&P) strategy (pacemaker implantation followed by atrio-ventricular junction ablation (AVJA)) is superior to medical therapy in improving quality of life and prognosis. Despite its well-proven benefits, this invasive therapeutic option is still underutilized in clinical practice. The choice of pacing modality (right ventricular pacing, biventricular pacing, BVP, or conduction system pacing, CSP) is crucial and can have significant clinical implications.

View Article and Find Full Text PDF

Background: In the last years, the Cor-Knot device has been increasingly used in heart valve surgery. Our aim was to investigate the incidence of valvular complications in patients who underwent valvular surgery using the Cor-Knot device in multicentric cohorts at one-year follow-up.

Methods: Three hundred and sixty-eight patient underwent heart valve repair or replacement surgery using automated titanium suture fasteners in four cardiothoracic surgery departments between September 2018 and January 2020.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!