Globally growing problems related to cardiovascular diseases lead to a considerable need for synthetic vascular grafts. For small-caliber vascular prosthesis, it remains essential to fulfill rapid endothelialization, inhibit intimal hyperplasia, and prevent calcification for keeping patency. To modulate vascular regeneration, herein, we developed a bioactive trilayered tissue-engineered vascular graft encapsulating both microRNA-126 and microRNA-145 in the fibrous inner and middle layers, respectively. In vitro cell activities demonstrated that the trilayered electrospun membranes had significant biological advantages in enhanced growth and intracellular nitric oxide production of vascular endothelial cells, modulation of phenotypes of vascular smooth muscle cells (SMCs), and restraint of calcium deposition through fast-releasing microRNA-126 and slow-releasing microRNA-145. Histological and immunofluorescent analyses of in vivo implantation in a rat abdominal aorta interposition model suggested that the dual-microRNA-loading trilayered electrospun graft exerted a positive effect on accelerating endothelialization, improving contractile SMC regeneration, and promoting normal extracellular matrix formation. Meanwhile, the local bioactivity of microRNA-126 and microRNA-145 in the trilayered vascular graft could regulate inflammation and depress calcification possibly by facilitating transformation of macrophages into the anti-inflammatory M2 phenotype. These findings indicated that the trilayered electrospun graft by local delivery of dual microRNAs could be possibly used as a bioactive substitute for replacement of artificial small-caliber blood vessels.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.9b19452 | DOI Listing |
Biomed Mater Eng
July 2024
Department of Polymer and Materials Research, University of Sonora, Hermosillo, Mexico.
Background: Polymeric electrospun mats have been used as scaffolds in tissue engineering for the development of novel materials due to its characteristics. The usage of synthetic materials has gone in decline due to environmental problems associated with their synthesis and waste disposal. Biomaterials such as biopolymers have been used recently due to good compatibility on biological applications and sustainability.
View Article and Find Full Text PDFACS Biomater Sci Eng
March 2024
Department of Biological Sciences and Bioengineering, Indian Institute of Technology Kanpur, Kanpur 208016, U.P., India.
Vascular grafts with a small diameter encounter inadequate patency as a result of intimal hyperplasia development. In the current study, trilayered electrospun small-diameter vascular grafts (PU-PGACL + GA) were fabricated using a poly(glycolic acid) and poly(caprolactone) blend as the middle layer and antioxidant polyurethane with gallic acid as the innermost and outermost layers. The scaffolds exhibited good biocompatibility and mechanical properties, as evidenced by their 6 MPa elastic modulus, 4 N suture retention strength, and 2500 mmHg burst pressure.
View Article and Find Full Text PDFJ Mater Sci Mater Med
January 2024
Department of Mechanical Engineering and Aeronautics, Laboratory of Biomechanics and Biomedical Engineering, University of Patras, Patras, GR, Greece.
Tissue engineering scaffolds as three-dimensional substrates may serve as ideal templates for tissue regeneration by simulating the structure of the extracellular matrix (ECM). Many biodegradable synthetic polymers, either hydrophobic, like Poly-ε-caprolactone (PCL), or hydrophilic, like Poly(Vinyl Alcohol) (PVA), are widely used as candidate bioactive materials for fabricating tissue engineering scaffolds. However, a combination of good cytocompatibility of hydrophilic polymers with good biomechanical performance of hydrophobic polymers could be beneficial for the in vivo performance of the scaffolds.
View Article and Find Full Text PDFInt J Biol Macromol
March 2024
Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran; Cellular and Molecular Research Group, Institute of Biotechnology, Ferdowsi University of Mashhad, Iran. Electronic address:
The electrospun nanofibers and porous scaffolds hold great promise in regenerative medicine. A novel nanofiber-hydrogel‑silicone tri-layer wound dressing has been designed and fabricated to address the limitations of each platform. The bottom nanofiber layer with a 110 mm diameter meets the wound surface and regulates cell attachment and migration.
View Article and Find Full Text PDFBiomed Mater
January 2024
Regenerative Medicine Group, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
Regeneration of damaged urethral tissue remains a major challenge in the field of lower urinary tract reconstruction. To address this issue, various synthetic and natural biodegradable biomaterials are currently being explored for the fabrication of scaffolds that promote urethral regeneration and healing. In this study, we present an approach to fabricate a trilayer hybrid scaffold comprising a central layer of poly(lactic acid) (PLA) between two layers of chitosan.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!