Objective: The objective was to compare first-attempt intubation success using direct laryngoscopy augmented by laryngeal manipulation, ramped patient positioning, and use of a bougie (A-DL) with unaided video laryngoscopy (VL) in adult emergency department (ED) intubations.
Methods: This study was a secondary analysis of a multicenter prospective observational database of ED intubations from the National Emergency Airway Registry (NEAR). We compared all VL procedures to seven exploratory permutations of A-DL using multivariable regression models. We further stratified by blade shape into hyperangulated VL (HA-VL) and standard-geometry VL (SG-VL). We report differences in first-attempt intubation success and peri-intubation adverse events with cluster-adjusted odds ratios (ORs) with 95% confidence intervals (CIs). We report univariate comparisons in patient characteristics, difficult airway attributes, and intubation methods using descriptive statistics and OR with 95% CI.
Results: We analyzed 11,714 intubations performed from January 1, 2016, through December 31, 2017. Of these encounters, 6,938 underwent orotracheal intubation with either A-DL or unaided VL on first attempt. A-DL was used first in 3,936 (56.7%, 95% CI = 46.9 to 66.5) versus unaided VL in 3,002 (43.3%, 95% CI = 33.5 to 53.1). Of the A-DL first intubations 1,787 (45.4%) employed ramped positioning alone, 1,472 (37.4%) had external laryngeal manipulation (ELM), and 365 (9.3%) used a bougie. Rapid sequence intubation (RSI) was the most common method used in 5,602 (80.8%, 95% CI = 77.0 to 84.5) cases. First-attempt success was significantly higher with all VL (90.9%, 95% CI = 88.7 to 93.1) versus all A-DL (81.1%, 95% CI = 78.7 to 83.5) despite the VL group having more patients with reduced mouth opening, neck immobility, and an initial impression of airway difficult. Multivariable regression analyses controlling for indication, method, operator specialty and year of training, center clustering, and all registry-recorded difficult airway predictors revealed first-attempt success was higher with all unaided VL compared with any A-DL (adjusted OR [AOR] = 2.8, 95% CI = 2.4 to 3.3), DL with bougie (AOR = 2.7, 95% CI = 2.1 to 3.5), DL with ELM (AOR = 1.8, 95% CI = 1.5 to 2.2), DL with ramped positioning (AOR = 2.8, 95% CI = 2.3 to 3.3), or DL with ELM plus bougie (AOR = 2.8, 95% CI = 2.3 to 3.3). Subgroup analyses of HA-VL and SG-VL compared with any A-DL yielded similar results (AOR = 3.2, 95% CI = 2.6 to 3.0; and AOR = 2.4, 95% CI = 1.9 to 3.0, respectively). The propensity score-adjusted odds for first-attempt success with VL was also 2.8 (95% CI = 2.4 to 3.3). Fewer esophageal intubations were observed in the VL cohort (0.4% vs. 1.3%, AOR = 0.2, 95% CI = 0.1 to 0.5).
Conclusions: Video laryngoscopy used without any augmenting maneuver, device, or technique results in higher first-attempt success than does DL that is augmented by use of a bougie, ELM, ramping, or combinations thereof.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/acem.13851 | DOI Listing |
J Endovasc Ther
April 2018
1 Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Italy.
Purpose: To assess early and midterm outcomes of iliac branch device (IBD) implantation without an aortic stent-graft for the treatment of isolated common iliac artery aneurysm (CIAA).
Methods: From December 2006 to June 2016, 49 isolated CIAAs in 46 patients were treated solely with an IBD at 7 vascular centers. Five patients were lost to follow-up, leaving 41 male patients (mean age 72.
J Vasc Surg
September 2017
Division of Vascular Surgery, Mayo Clinic, Rochester, Minn.
Objective: The GORE EXCLUDER Iliac Branch Endoprosthesis (IBE; W. L. Gore and Associates, Flagstaff, Ariz) is an iliac branch stent graft system designed to preserve internal iliac artery perfusion during endovascular repair of aortoiliac aneurysms (AIAs) and common iliac artery (CIA) aneurysms (CIAAs).
View Article and Find Full Text PDFInt Angiol
June 2017
Department of Cardiovascular Surgery, Tokyo Medical University, Tokyo, Japan.
J Vasc Surg
June 2008
Division of Vascular Surgery, Gonda Vascular Center, Mayo Clinic, Rochester, MN 55905, USA.
Objectives: To assess expansion rate of common iliac artery aneurysms (CIAAs) and define outcomes after open repair (OR) and endovascular repair (EVAR).
Methods: Clinical data of 438 patients with 715 CIAAs treated between 1986 and 2005 were retrospectively reviewed. Size, presentations, treatments, and outcomes were recorded.
Diabetes
November 1987
Research Division, the Joslin Diabetes Center, Boston, MA 02215.
A quantitative fluid-phase radioassay for autoantibodies reacting with insulin (competitive insulin autoantibody assay, CIAA) was developed. The assay's features include 1) use of a physiologic amount of 125I-labeled insulin, 2) parallel incubations with supraphysiologic cold insulin (competitive), and 3) an incubation time of 7 days and a single-step multiple-wash polyethylene glycol separation. Mean +/- SE CIAA levels in 50 controls were 8 +/- 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!