First Experience of Transcatheter Leak Occlusion With Detachable Coils Following Left Atrial Appendage Closure.

JACC Cardiovasc Interv

Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas; Interventional Electrophysiology, Scripps Clinic, La Jolla, California; Department of Cardiology, MetroHealth Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio; Division of Cardiology, Stanford University, Stanford, California; Dell Medical School, University of Texas, Austin, Texas.

Published: February 2020

Objectives: The aim of this study was to assess the feasibility and efficacy of transcatheter leak closure with detachable coils in patients with incomplete left atrial appendage (LAA) closure.

Background: Incomplete LAA closure is common after interventional therapies targeting the LAA, potentially hindering effective thromboembolic prevention. Detachable coils have found a wide range of applications for transcatheter vascular occlusion and embolization procedures.

Methods: Thirty consecutive patients at high thromboembolic risk with clinically relevant residual leaks (mean age 72 ± 9 years, 73.3% men, mean CHADS-VASc score 4.4 ± 1.4, mean HAS-BLED score 3.6 ± 0.8) underwent percutaneous closure of the LAA patency using embolization coils. Transesophageal echocardiography was performed at 60 ± 15 days post-procedure.

Results: LAA closure had been previously attempted with the Watchman device in 25 patients, the Amulet device in 2 patients, and the LARIAT device in 3 patients. Baseline transesophageal echocardiography documented moderate and severe leaks in 20 (66.7%) and 10 (33.3%) patients, respectively. After a single procedure, 25 patients (83.3%) showed complete LAA sealing or minimal leaks. Five patients (16.7%) had moderate residual leaks; 3 patients of them were offered repeat procedures. Mean procedure and fluoroscopy times were 76 ± 41 min and 21 ± 14 min, respectively; the mean volume of iodinated contrast medium used was 80 ± 47 ml. Coil deployment was successful in all cases. The overall complication rate was 6.1%. After a median follow-up period of 54 days (range 43 to 265 days) and an average of 1.1 procedures/patient, transesophageal echocardiography revealed complete LAA sealing or negligible residual leaks in 28 patients (93.3%; 25 with no residual leak, 3 patients with minimal to mild residual leaks) and moderate residual leaks in 2 patients (6.7%).

Conclusions: Transcatheter LAA leak occlusion using endovascular coils appears to be a safe, effective, and promising approach in patients at high echo time risk with incomplete LAA closure. (Transcatheter Leak Closure With Detachable Coils Following Incomplete Left Atrial Appendage Closure Procedures [TREASURE]; NCT03503253).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2019.10.022DOI Listing

Publication Analysis

Top Keywords

residual leaks
20
detachable coils
16
transcatheter leak
12
laa closure
12
transesophageal echocardiography
12
leaks patients
12
patients
11
laa
9
leak occlusion
8
closure
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!