A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Importance of Distal Sealing during Endovascular Aneurysm Repair Using Aneurysmal Common Iliac Artery as Landing Zone. | LitMetric

Background: Although the use of aneurysmal common iliac artery (CIA) as the landing zone during endovascular aortic aneurysm repair EVAR remains an essential procedure, this procedure may increase the risk of late complications such as ongoing CIA dilatation and type Ib endoleak (CIA-related complications). We hypothesized that incomplete sealing of the aneurysmal CIA segment during EVAR could increase the incidence of CIA-related complications. In this study, we evaluated the midterm results of EVAR with aneurysmal CIA used as the landing zone and assessed the importance of distal sealing in this procedure.

Methods: We retrospectively reviewed all cases of endovascular aneurysm repair using CIA as landing zone between 2007 and 2015 that had at least 3 years' follow-up. We defined aneurysmal CIA as maximum diameter ≥18 mm. The main outcome was the incidence of CIA-related complications. We compared midterm results between normal CIA and aneurysmal CIA. Next, we analyzed risk factors for CIA-related complications in aneurysmal CIA.

Results: Four complications occurred in normal CIA (mean follow-up, 66.5 ± 22.1 months); 21 occurred in aneurysmal CIA (mean follow-up, 62.2 ± 20.5 months). The 5-year portion of freedom from CIA-related complications was 97.3% in normal CIA and 69.4% in aneurysmal CIA (P < 0.001). Multivariable analysis in aneurysmal CIA showed that unsealed CIA segment length was only risk factor for CIA-related complications. Given the receiver operating characteristic curve results, we defined the unsealed CIA segment ≥10 mm as incomplete sealing. The hazard ratio for incomplete sealing associated with CIA-related complications was 3.92 (95% confidence interval 1.62-9.46, P = 0.02).

Conclusions: Use of aneurysmal CIA as landing zone increases the risk of CIA-related complications. However, maximum sealing of the aneurysmal CIA segment could prevent these complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.avsg.2020.01.009DOI Listing

Publication Analysis

Top Keywords

aneurysmal cia
24
cia-related complications
20
landing zone
16
aneurysm repair
12
cia
12
cia landing
12
normal cia
12
aneurysmal
9
distal sealing
8
endovascular aneurysm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!