Age-related Macular Degeneration (AMD) is one of the common diseases affecting the posterior part of the eye, of a large population above 45 years old. Anti-Vascular Endothelial Growth Factor- A (Anti-VEGF-A) agents have been considered and approved as therapeutic agents for the treatment of AMD. Due to the large molecular weight and poor permeability through various eye membranes, VEGF-A inhibitors are given through an intravitreal injection, even though the delivery of small therapeutic molecules by topical application to the posterior part of the eye exhibits challenges in the treatment. To overcome these limitations, nanocarrier based delivery systems have been utilized to a large extent for the delivery of therapeutics. Nanocarriers system offers prodigious benefits for the delivery of therapeutics to the posterior part of the eye in both invasive and non-invasive techniques. The nano size can improve the permeation of therapeutic agent across the biological membranes. They provide protection from enzymes present at the site, targeted delivery or binding with the disease site and extend the release of therapeutic agents with prolonged retention. This leads to improved therapeutic efficacy, patient compliance, and cost effectiveness of therapy with minimum dose associated side-effects. This review has summarized various nanocarriers explored for the treatment of AMD and challenges in translation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2174/1872211314666200117095917 | DOI Listing |
JBJS Essent Surg Tech
January 2025
Department of Neurosurgery, Center for Neuroscience and Spine, Virginia Mason Medical Center, Seattle, Washington.
Background: Prone transpsoas lumbar interbody fusion (PTP) is a newer technique to treat various spinal disc pathologies. PTP is a variation of lateral lumbar interbody fusion (LLIF) that is performed with the patient prone rather than in the lateral decubitus position. This approach offers similar benefits of lateral spinal surgery, which include less blood loss, shorter hospital stay, and quicker recovery compared with traditional open spine surgery.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Aier Institute of Refractive Surgery, Refractive Surgery Center, Guangzhou Aier Eye Hospital, Guangzhou, China.
Background: Whether the correlations between anterior and posterior corneal parameters vary according to different conditions is unknown. We aimed to investigate the anterior-to-posterior correlations of corneal parameters according to different refractive status and anterior segment dimension.
Methods: A total of 8,365 myopic eyes undergoing refractive surgery between 2017 and 2019 from multiple ophthalmic centers were consecutively included in the study.
BMC Ophthalmol
January 2025
Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Rd., Haidian District, Beijing, China.
Background: This study aims to comprehensively evaluate the predictive accuracy of six widely used toric intraocular lens (IOL) calculators in eyes undergoing cataract surgery with toric IOL implantation.
Methods: This retrospective study reviewed 53 eyes of 53 patients that underwent cataract extraction with toric IOL implantation using Zeiss 709 M. Six toric IOL calculators were evaluated: Barrett toric calculator (with predicted PCA, measured PCA, and TK), Kane formula (predicted PCA), and EVO 2.
BMC Ophthalmol
January 2025
Dept. of Retina and Vitreous, Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, India.
Purpose: To report a rare case of a Coats-like response developing after vitreoretinal surgery for proliferative diabetic retinopathy (PDR) and its successful management with retinal laser photocoagulation and adjunctive intravitreal steroids.
Case Description: A 52-year-old woman with a five-year history of type 2 diabetes mellitus and hypertension presented with decreased vision in the left eye (counting fingers at 1 m). Examination revealed high-risk PDR in both eyes, with a subtotal macula-off combined retinal detachment in the left eye.
BMC Ophthalmol
January 2025
Department of Refractive Surgery, Guangzhou Aier Eye Hospital, Jinan University, Guangzhou City, Guangdong Province, 510000, China.
Purpose: To evaluate the impact of Implantable Collamer Lens (ICL) implantation on anterior chamber angle parameters and posterior segment structures in highly myopic eyes and explore potential correlations between these changes. The study aimed to assess alterations in superficial and deep vessel density (SVD, DVD), foveal avascular zone (FAZ) area, and retinal nerve fiber layer (RNFL) thickness to clarify the safety profile of ICL implantation.
Methods: Prospective observational study, included 36 highly myopic eyes undergoing ICL implantation in surgery group and 23 non-surgical control eyes in non-surgery group.