Background and Purpose- This study aimed to derive and validate an optimal collateral measurement on computed tomographic perfusion imaging for patients with acute ischemic stroke. Methods- In step 1 analysis of 22 patients, the parasagittal region of the ischemic hemisphere was divided into 6 pial arterial zones to derive the optimal collateral threshold by receiver operating characteristic analysis. The collateral threshold was then used to define the collateral index in step 2. In step 2 analysis of 156 patients, the computed tomographic perfusion collateral index was compared with collateral scores on dynamic computed tomographic angiography in predicting good clinical outcome by simple regression. Results- The optimal collateral threshold was delay time >6 s (sensitivity, 88%; specificity, 92%). The computed tomographic perfusion collateral index, defined by the ratio of delay time >6 s/delay time >2 s volume, showed a significant correlation with dynamic computed tomographic angiography collateral scores (correlation coefficient, 0.62; <0.001), with an optimal cut point of 31.8% in predicting good collateral status (sensitivity of 83% and specificity of 86%). When predicting good clinical outcome, the delay time collateral index showed a similar predictive power to dynamic computed tomographic angiography collaterals (area under the curve, 0.78 [0.67-0.83] and 0.77 [0.69-0.84], respectively; <0.001). Conclusions- Computed tomographic perfusion can accurately quantify collateral flow after acute ischemic stroke.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/STROKEAHA.119.028284 | DOI Listing |
JACC Case Rep
January 2025
Interventional Cardiology Section, Division of Cardiovascular Medicine, Department of Medicine, Stanford University School of Medicine, Stanford, California, USA.
Aneurysms of the interventricular membranous septum are a rare anatomical feature that can be detected incidentally on computed tomography or echocardiography. Such aneurysms can pose challenges in the treatment of patients with aortic valve stenosis. A case series of 2 patients with membranous septal aneurysms treated successfully with current-generation balloon-expandable and self-expanding transcatheter heart valves is presented here.
View Article and Find Full Text PDFAm J Transl Res
December 2024
Respiratory and Critical Care Medicine, Nan'an City Hospital Quanzhou 362399, Fujian, China.
Objective: To evaluate the application value of CT diagnostic technology based on the Shukun Imaging Post-Processing System for early screening and diagnosis of lung cancer.
Methods: A total of 35 patients diagnosed with lung cancer postoperatively and 53 patients with benign nodules were included in this retrospective study, all of whom were treated in the Department of Thoracic and Cardiovascular Surgery of the Second Affiliated Hospital of Fujian Medical University from January 2020 to December 2023. All patients underwent chest spiral CT examinations.
Cureus
December 2024
Department of Medical Checkup, Naha City Hospital, Naha, JPN.
Isolated fallopian tube torsion (IFTT) is a rare cause of surgical emergency and is difficult to diagnose. We present a case of IFTT in a 14-year-old girl who presented with an acute abdomen. Based on the clinical and computed tomographic findings, an initial diagnosis of ovarian torsion was considered.
View Article and Find Full Text PDFVet Radiol Ultrasound
January 2025
AniCura Istituto Veterinario Novara, Monticello, Italy.
With the advancement in imaging technology, ECG-gated cardiac multidetector computed tomography (MDCT) has emerged as a tool for the anatomic evaluation of the pulmonary valve and right ventricular outflow tract (RVOT) in human medicine. Currently, the evaluation of the pulmonary valve relies primarily on echocardiographic examination. However, the bi-dimensional nature of this technique and the location/orientation of the pulmonary valve in the thoracic cavity can pose challenges.
View Article and Find Full Text PDFVet Res Commun
January 2025
Division of Animal Anatomy, Department of Biostructure and Animal Physiology, Faculty of Veterinary Medicine, Wroclaw University of Environmental and Life Sciences, Wrocław, Poland.
Clinically, the rodent thorax is important because of the variety of problems that may affect the heart, lungs, and other thoracic structures. Syrian hamsters are the most common pet and experimental hamster species. Sectional imaging of small mammals is widely increasing in use for clinical and research settings; however, no reports on the thoracic sectional imaging anatomy in this species have been made.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!