A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Infrared Thermographic Evaluation of Temperature Modifications Induced during Implant Site Preparation with Steel vs. Zirconia Implant Drill. | LitMetric

Infrared Thermographic Evaluation of Temperature Modifications Induced during Implant Site Preparation with Steel vs. Zirconia Implant Drill.

J Clin Med

International Academy of Ceramic Implantology, Zirconia Implant Research Group (Z.I.R.G), Silver Spring, MD 20910, USA.

Published: January 2020

Background: The heat produced during implant site osteotomy can potentially interfere with and influence the osseointegration process of a dental implant. The objective of this in vitro investigation was to measure the temperature changes during simulated osteotomies in bovine rib bone. The measurements were made at the apical area of the osteotomies with steel implant drills compared to zirconia implant drills.

Methods: Steel cylindrical drills (2 mm) and zirconia cylindrical drills (2 mm) were evaluated in vitro using bovine rib bone for a total of five groups based on the number of osteotomies performed with each drill: 10, 20, 40, 90, or 120 osteotomies. Bone and apical drill temperatures were measured by means of infrared thermography. The drilling time for each osteotomy was measured for each preparation.

Results: Statistically significant differences were found in the temperature measurements in the bone and apical portion of the drills between the study groups ( < 0.05). A statistically significant difference was observed for drilling time preparation between steel cylindrical drill (2 mm) and zirconia cylindrical drills (2 mm) ( < 0.01).

Conclusions: The drill material has an impact on the temperature changes that occur at its apical portion during bone preparation for implant placement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7019482PMC
http://dx.doi.org/10.3390/jcm9010148DOI Listing

Publication Analysis

Top Keywords

cylindrical drills
12
implant site
8
preparation steel
8
zirconia implant
8
temperature changes
8
bovine rib
8
rib bone
8
steel cylindrical
8
zirconia cylindrical
8
bone apical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!