Diameter and volume are frequently used parameters for cardiovascular diagnosis, e.g., to identify a stenosis of the coronary arteries. Intra-vascular OCT imaging has a high spatial resolution and promises accurate estimates of the vessel diameter. However, the actual images are reconstructed from A-scans relative to the catheter tip and imaging is subject to rotational artifacts. We study the impact of different volume reconstruction approaches on the accuracy of the vessel shape estimate. Using X-ray angiography we obtain the 3D vessel centerline and the 3D catheter trajectory, and we propose to align the A-scans using both. For comparison we consider reconstruction along a straight line and along the centerline. All methods are evaluated based on an experimental setup using a clinical angiography system and a vessel phantom with known shape. Our results illustrate potential pitfalls in the estimation of the vessel shape, particularly when the vessel is curved. We demonstrate that the conventional reconstruction approaches may result in an overestimate of the cross-section and that the proposed approach results in a good shape agreement in general and for curver segments, with DICE coefficients of approximately 0.96 and 0.98, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC.2019.8857712 | DOI Listing |
Pol J Vet Sci
June 2024
Department and Clinic of Animal Surgery, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, Głęboka 30, 20-612 Lublin, Poland.
The aim of the study was to determine the thickness of choroidal layers in mixed breed dogs suffering from retinal atrophy (RA) and showing symptoms of progressive retinal atrophy (PRA), with the use of SD-OCT. The study was performed on 50 dogs divided into two groups: 25 dogs diagnosed with retinal atrophy (RA) with PRA symptoms aged 1.5-14 years and 25 healthy dogs aged 2-12 years.
View Article and Find Full Text PDFCJC Open
December 2024
Schulich Heart Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
Background: Cardiac computed tomography imaging with contrast is being used increasingly to image left atrial appendage occlusion (LAAO) devices. Contrast flow across a device, also known as a transfabric leak (TFL), may indicate a lack of complete LAAO-device endothelialization. The data on the rate, predictors, and clinical events associated with TFL are limited.
View Article and Find Full Text PDFJTO Clin Res Rep
December 2024
Department of Pulmonary Diseases, GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Center+, Maastricht, The Netherlands.
This review discusses the current data on predictive and prognostic biomarkers in oligometastatic NSCLC and discusses whether biomarkers identified in other stages and widespread metastatic disease can be extrapolated to the oligometastatic disease (OMD) setting. Research is underway to explore the prognostic and predictive value of biological attributes of tumor tissue, circulating cells, the tumor microenvironment, and imaging findings as biomarkers of oligometastatic NSCLC. Biomarkers that help define true OMD and predict outcomes are needed for patient selection for oligometastatic treatment, and to avoid futile treatments in patients that will not benefit from locoregional treatment.
View Article and Find Full Text PDFIndian J Orthop
January 2025
Department of Orthopaedic Surgery, Hillel Yaffe M.C., 3100 Hadera, Israel.
Objective: To present the clinical result of spinal fixation system made entirely of Carbon-Fiber-Reinforced (CFR)-Hybrid Polyaryl-Ether-Ether-Ketone (PEEK).
Summary Of Background Data: Fusion surgery has been used to treat chronic low back pain caused by degenerative disk disease (DDD). The traditional pedicle screw system made of titanium, though biocompatible, can lead to complications, such as stress shielding and implant failure.
This article discusses infection, a zoonotic parasite that lives in the liver bile ducts. A 31-year-old female patient was diagnosed with symptoms such as nausea, increased liver enzymes, and right upper quadrant pain for about a year. The parasite was detected in the common bile duct by Endoscopic Ultrasound (EUS) and removed by Endoscopic Retrograde Cholangio Pancreatography (ERCP).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!