People with a transtibial amputation worldwide rely on their prosthetic socket to regain their mobility. Patient comfort is largely affected by the weight and strength of these prosthetic sockets. The use of additive manufacturing could give the prosthetist a range of new design possibilities when designing a prosthetic socket. These new design possibilities can in turn lead to improved socket designs and more comfortable prosthetic sockets. This new way of designing and producing prosthetic sockets radically differs from the manual traditional production process. This makes it difficult for prosthetists to understand how all these new design possibilities influence the mechanical properties of the additive manufactured prosthetic socket. Therefore there is a growing need for a method to evaluate the strength and stiffness of newly developed socket designs.We propose a method to evaluate the strength and stiffness of prosthetic sockets. A robotic gait simulator is used to apply realistic kinetics of amputee gait to the tested socket. A Digital Image Correlation (DIC) system is then used to measure the deformation of a prosthetic socket under different loading conditions. This way it is possible to check if plastic deformation will occur in the designed transtibial socket. Furthermore it is possible to assess the effect of cyclic loading on the 3D printed socket.To illustrate the proposed method, a transtibial prosthetic socket was designed using CAD software and produced with laser sintering PA12. DIC measurements were performed on this transtibial socket both before and after it was subjected to a cyclic load of 1 million cycles (mimicking realistic amputee gait).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC.2019.8856544 | DOI Listing |
Front Bioeng Biotechnol
December 2024
Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.
In this work, a cost-effective, scalable pneumatic silicone actuator array is introduced, designed to dynamically conform to the user's skin and thereby alleviate localised pressure within a prosthetic socket. The appropriate constitutive models for developing a finite element representation of these actuators are systematically identified, parametrised, and validated. Employing this computational framework, the surface deformation fields induced by 270 variations in soft actuator array design parameters under realistic load conditions are examined, achieving predictive accuracies within 70 µm.
View Article and Find Full Text PDFJ Oral Biol Craniofac Res
December 2024
Department of dental materials, Faculty of Dentistry Medicine, Universitas Airlangga, Indonesia.
Background: Tooth extraction without socket preservation will lead to reduction in the dimensions and volume of the alveolar bone. Bone defects resulting from tooth extraction not only hinder prosthetic reconstruction but also present aesthetic issues and complicating dental implant treatment. Purple leaves contains flavonoids, steroids, tannins, saponins,and non-toxic alkaloids.
View Article and Find Full Text PDFJ Prosthodont Res
January 2025
Department of Masticatory Function and Health Science, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
Purpose: To compare the stress distribution in loaded zirconia resin-bonded fixed dental prostheses (RBFDPs) and periodontal tissue using finite element analysis, considering reduced alveolar bone levels and the number of retainers.
Methods: A human skull was micro-CT scanned. Three framework designs were tested: a 2-unit RBFDP using the maxillary left central incisor (#21) as an abutment, another using a canine (#23), and a 3-unit RBFDP using both #21 and #23.
Plast Aesthet Nurs (Phila)
December 2024
Sowmya Srinivas, BDS, MDS, PhD, is an Assistant Professor at the Department of Prosthodontics, JSS Dental College and Hospital, JSS Academy of Higher Education and Research, Mysore, Karnataka, India.
Placing an implant immediately into extraction sockets provides a distinct advantage over delayed placement, eliminating the need for a 4 to 6 months waiting period for bone formation. However, when patients present with hypothyroidism, the feasibility of immediate placement of dental implants becomes uncertain. This case involved a hypothyroid woman in her late 60s with loose lower anterior teeth.
View Article and Find Full Text PDFProsthet Orthot Int
December 2024
School of Intelligent Rehabilitation Engineering, Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.
Background: Prosthetic socket is a key component of the prosthesis for clinical application; its performance directly affects the adaptation of the residual limb to the prosthetic socket. There are long-term and short-term volume fluctuation of the residual limb. The volume fluctuation of the residual limb will lead to the pressure mismatch at the interface of the residual limb and the prosthetic socket, which will cause a series of skin and fit problems.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!