A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Continuous Assessment of Carotid Diameter using an Accelerometer Patch Probe for Ambulatory Arterial Stiffness Monitoring. | LitMetric

We present a system with an accelerometer patch probe design for non-invasive evaluation of carotid arterial stiffness. The proposed system could continuously measure the acceleration signal derived due to the propagation of blood pulse wave through the left carotid artery, double integrating and scaling it to estimate the accelerometer-derived carotid wall displacement. This functional principle was proved by comparing the accelerometer-derived carotid wall displacement with the carotid distension signal from the reference system ARTSENS® (ARTerial Stiffness Evaluation for Noninvasive Screening device) for all the recruited human subjects. Assuming the relationship to be linear, a one-time subject-specific calibration was performed with the simultaneously acquired reference distension signal and the accelerometer-derived carotid displacement signals on its anachrotic limbs data points (at systolic phases) for each subject. This calibration equation was tested with latterly acquired accelerometer signals and results in the measurement of accelerometer-derived carotid distension and lumen-diameter values. The ability of the accelerometer system to measure real-time carotid distension and lumen diameter in a repeatable beat-by-beat manner for arterial stiffness index evaluation was validated in-vivo. The accuracy of the obtained results was studied with our clinically validated reference system. The experimental validation study results exhibit the feasibility of using the developed accelerometer system for continuous carotid distension and lumen diameter measurements, whereby the estimation of carotid arterial stiffness.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2019.8857330DOI Listing

Publication Analysis

Top Keywords

arterial stiffness
20
accelerometer-derived carotid
16
carotid distension
16
carotid
11
accelerometer patch
8
patch probe
8
carotid arterial
8
carotid wall
8
wall displacement
8
distension signal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!