Spastic Cerebral Palsy is the most common type of Cerebral Palsy (CP) that affects muscle coordination and control. Using Radiofrequency Ablation (RFA) to target the motor branches of the median and ulnar nerve may provide an additional treatment to Botulinum Toxin for spasticity in the hand. However, there are a limited number of studies that report the use of RFA in treating upper-limb spasticity. This prompts the need to establish a simulation model that has been tested against physical phantom to help determine the efficacy of RFA as a treatment for spasticity. In this study, a 3D COMSOL Multiphysics model of a commercial RF probe was validated against a Thermochromic Liquid Crystal (TLC) homogeneous gel phantom. The results of the COMSOL model were compared to the TLC phantom in terms of temperature (0.42 ± 1.06°C for the TLC high temperature range and -1.90 ± 0.88°C for the TLC low temperature range), lesion shape (14.5 ± 5.0%) and lesion size (0.18 ± 0.06 mm). These results show that COMSOL Multiphysics may be feasible as a tool to characterise RF lesions if the reported errors are accounted for. Further work is required to develop a more complex COMSOL model that incorporates different tissue aspects. However, this is a first step to establishing a validated COMSOL model of a RF probe in homogeneous muscle tissue.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2019.8856962DOI Listing

Publication Analysis

Top Keywords

comsol model
12
radiofrequency ablation
8
physical phantom
8
cerebral palsy
8
comsol multiphysics
8
temperature range
8
model
5
comsol
5
experimental validation
4
validation multiphysics
4

Similar Publications

Design and Study of Pulsed Eddy Current Sensor for Detecting Surface Defects in Small-Diameter Bars.

Sensors (Basel)

December 2024

College of Automation & College of Artificial Intelligence, Nanjing University of Posts and Telecommunications, Nanjing 210023, China.

The design and study of pulsed eddy current sensors for detecting surface defects in small-diameter rods are highly significant. Accurate detection and identification of surface defects in small-diameter rods may be attained by the ongoing optimization of sensor design and enhancement of detection technologies. This article presents the construction of a non-coaxial differential eddy current sensor (Tx-Rx sensor) and examines the detection of surface defects in a small diameter bar.

View Article and Find Full Text PDF

Numerical Investigation of a Microfluidic Biosensor Based on I-Shaped Micropillar Array Electrodes.

Sensors (Basel)

December 2024

Department of Electrical and Computer Engineering, Bucknell University, Lewisburg, PA 17837, USA.

Micropillar array electrodes offer several advantages, such as enhanced mass transport, lower detection limits, and the potential for miniaturization, making them instrumental in the design and fabrication of electrochemical biosensors. The performance of these biosensors is influenced by electrode geometry, including parameters like shape and height, which affect surface area and overall sensitivity. In this study, we designed a microfluidic electrochemical biosensor featuring micropillar array electrodes, modeled in COMSOL Multiphysics.

View Article and Find Full Text PDF

The cleanliness of lubricating oil plays a key role in determining the operational health of mechanical systems, serving as a critical metric that delineates the extent of equipment wear. In this study, we present a magnetic-core-type planar coil particle detection sensor. The detection accuracy and detection limit are improved by optimizing the magnetic field inside the sensor.

View Article and Find Full Text PDF

The placenta plays a critical role in nutrient and oxygen exchange during pregnancy, yet the effects of medicinal drugs on this selective barrier remain poorly understood. To overcome this, this study presents a cost-effective bioimpedance spectroscopy (BIS) system to assess tight junction integrity and monolayer formation in BeWo b30 cells, a widely used model of the multinucleated maternal-fetal exchange surface of the placental barrier. Cells were cultured on collagen-coated porous membranes and treated with forskolin to induce controlled syncytialization.

View Article and Find Full Text PDF
Article Synopsis
  • This study investigates the stress distribution in MEMS infrared light sources and develops an optimal thickness for supporting films to minimize stress and deformation.
  • By using advanced algorithms like the particle swarm algorithm and backpropagation neural networks, researchers enhance simulation data to better predict stress trends across various film thicknesses.
  • Comprehensive packaging solutions have been created to improve the thermal efficiency and stability of MEMS sensors in harsh conditions, ensuring their reliable operation compared to bare chips.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!