[First Experience with Cranioplasty Using the Polyetheretherketone (PEEK) Implant - Retrospective Five-Year Follow-up Study].

Acta Chir Orthop Traumatol Cech

Neurochirurgická klinika Fakultní nemocnice Královské Vinohrady a 3. lékařské fakulty Univerzity Karlovy, Praha.

Published: January 2020

PURPOSE OF THE STUDY Cranioplasty is currently the most common neurosurgical procedure. The purpose of this study is to describe the first experience with successful use of the Cranio-Oss (PEEK) custom implant for cranioplasty. MATERIAL AND METHODS In the period 2012 to 2013, a total of 26 cranioplasties were performed. In fourteen patients, their own bone flap was used for reconstruction. In four cases, a synthetic Cranio-Oss bone implant made of PEEK was used. In six patients, the defect was covered by an intraoperatively-made Palacos implant and in two cases, minor defects were covered with a titanium mesh. The patients were followed up for at least five years. Cranio-Oss is a cranial implant made from polyetheretherketone (PEEK), a synthetic biocompatible material. The implant is created using the CAD/CAM method in the shape of the bone defect based on the CT scan. Creating optimal roughness of the implant surface and of the surface of the contact area attached to the bone bed is controlled and included already in the strategy for machining individual areas of the implant during its manufacturing at a 5-axis machining centre. RESULTS The Cranio-Oss implant was used in four younger patients to cover larger and complex-shaped defects. The mean age of patients in this group was 47 years. The implant was fixed to the skull by micro-plates. In all the cases the wound healed well with good cosmetic results without the necessity of revision with respect to the used implant. The follow-up CT scans always showed the implant in situ with no signs of malposition. DISCUSSION Autologous bone flap is the most suitable material for defect reconstruction after craniectomy. This option is affordable and represents one of the best methods of reconstruction of defects after craniectomy in terms of cosmetic results. In some cases, the original skull cannot be used for cranioplasty (e.g. if destructed by tumourous process, infected or in comminuted fractures). In such cases, the defect needs to be managed using a synthetic implant. In case of extensive defects, the most suitable option is a custom made implant from advanced biomaterials. CONCLUSIONS Authors prefer using autologous bone flaps during cranioplasty. In cases where this method is unavailable, a synthetic bone substitute has to be used. The first medium-term experience with the use of a Cranio-Oss implant made of PEEK showed that it is a suitable alternative to the patient's own bone. No complications associated with this synthetic implant were reported and its use to manage skull defects can be strongly recommended. With respect to legal and accreditationrelated difficulties connected with bone fragments storage and thanks to the continuous cost reduction of synthetic implants will their importance grow in the future. Key words: decompressive craniectomy, bone substitute, craniotrauma.

Download full-text PDF

Source

Publication Analysis

Top Keywords

implant
16
bone
10
polyetheretherketone peek
8
purpose study
8
custom implant
8
bone flap
8
implant peek
8
cranio-oss implant
8
autologous bone
8
synthetic implant
8

Similar Publications

Reducing Healing Period with DDM/rhBMP-2 Grafting for Early Loading in Dental Implant Surgery.

Tissue Eng Regen Med

January 2025

Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, 172 Dolma-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea.

Background: Traditionally, dental implants require a healing period of 4 to 9 months for osseointegration, with longer recovery times considered when bone grafting is needed. This retrospective study evaluates the clinical efficacy of demineralized dentin matrix (DDM) combined with recombinant human bone morphogenetic protein-2 (rhBMP-2) during dental implant placement to expedite the osseointegration period for early loading.

Methods: Thirty patients (17 male, 13 female; mean age 55.

View Article and Find Full Text PDF

Background: Clavicle fractures associated with ipsilateral coracoid process fractures are very rare, with limited literature reporting only a few cases. This study reports on 27 patients with ipsilateral concomitant fractures of the clavicle and coracoid process who were followed for more than 12 months.

Material And Methods: This retrospective study reviewed the charts of skeletally mature patients with traumatic ipsilateral clavicle and coracoid process fractures treated at the authors' institution.

View Article and Find Full Text PDF

Introduction: Blunt traumatic aortic injury (TAI) is a critical condition and a leading cause of mortality in trauma patients, often resulting from high-speed accidents. Thoracic endovascular aortic repair (TEVAR) has developed into the preferred therapeutic approach due to its minimally invasive nature and promising outcomes. This study evaluates the safety and efficacy of TEVAR for managing TAI over a 10-year period at a Level-1 trauma center.

View Article and Find Full Text PDF

Objective: Soft tissue defects and postoperative wound healing complications related to calcaneus fractures may result in significant morbidity. The aim of this study was to investigate whether percutaneous minimally invasive screw internal fixation (PMISIF) can change this situation in the treatment of calcaneal fractures, and aimed to explore the mechanical effects of different internal fixation methods on Sanders type III calcaneal fractures through finite element analysis.

Methods: This retrospective analysis focused on 83 patients with Sanders II and III calcaneal fractures from March 2017 to March 2022.

View Article and Find Full Text PDF

Use of Brain Death Recipients in Xenotransplantation: A Double-Edged Sword.

Xenotransplantation

January 2025

Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Organ transplants are used to treat many end-stage diseases, but a shortage of donors means many patients cannot be treated. Xenogeneic organs have become an important part of filling the donor gap. Many current studies of kidney, heart, and liver xenotransplantation have used gene-edited pig organs on brain-dead recipients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!