Virtual Reality for PEripheral Regional Anesthesia (VR-PERLA Study).

J Clin Med

Department of Anaesthesiology and Intensive Care, Hôpital Saint-Antoine, Assistance Publique-Hôpitaux de Paris, 75012 Paris, France.

Published: January 2020

When used as an add-on to regional anesthesia, virtual reality (VR) has been reported to provide anxiety-reducing benefits and sedation-sparing effects. However, its impact on patient satisfaction is still a matter of controversy. We investigated the feasibility and benefits of implementing intraoperative VR distraction in a French University Hospital (Hôpital Saint-Antoine, AP-HP). This monocentric observational before-after study included 100 patients who underwent ambulatory upper limb surgery under peripheral nerve block in January 2019, 50 before and 50 after implementation of an intraoperative VR distraction protocol. Primary outcome was patient self-rated satisfaction score evaluated right after surgery. Secondary outcomes included 2-month patient-reported satisfaction score, perioperative self-rated anxiety and intraoperative hemodynamic changes. Compared to former standard care, VR distraction was associated with significantly higher postoperative satisfaction scores (10 [IQR 9; 10] vs. 9 [8; 10], < 0.001) still reported two months after surgery (10 [10;10] vs. 10 [8.5;10], = 0.06). Patient median intraoperative anxiety score was lower in the VR group, compared to Standard Care group (0 [0; 2] vs. 3 [0.25; 7], < 0.001), and occurrence of intraoperative hemodynamic changes was also lessened in the VR group (2% vs. 16%, 0R = 0.11[95% CI 0.002-0.87], = 0.031). The present findings suggest that VR distraction program in the operating room could effectively improve patient satisfaction with anxiety-reduction and hemodynamic benefits.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7019894PMC
http://dx.doi.org/10.3390/jcm9010215DOI Listing

Publication Analysis

Top Keywords

virtual reality
8
regional anesthesia
8
patient satisfaction
8
intraoperative distraction
8
satisfaction score
8
intraoperative hemodynamic
8
hemodynamic changes
8
compared standard
8
standard care
8
satisfaction
5

Similar Publications

Acceptance of Virtual Reality Training for Chemotherapy Administration Among Nursing Students.

Comput Inform Nurs

January 2025

Author Affiliations: Division of Hematology and Medical Oncology, Department of Internal Medicine, Wan Fang Hospital (Dr Chang), Department of Internal Medicine, School of Medicine, College of Medicine (Dr Chang), School of Nursing, College of Nursing (Tsai, Dr Huang), and Department of Nursing (Tsai, Lu, Huang) and Research Center in Nursing Clinical Practice (Tsai, Dr Huang), Wan Fang Hospital, Department of Nursing (Chan), and Cochrane Taiwan, Taipei Medical University (Dr Huang), Taipei, Taiwan; Department of Nursing, Faculty of Medicine, Universitas Pendidikan Ganesha, Bali, Indonesia (Gautama).

Virtual reality technology offers an extended and repeatable environment for delivering digital learning and training. This study investigated the acceptance of a smartphone virtual reality training program among nursing students for chemotherapy administration using a modified Technology Acceptance Model. The teaching materials for the chemotherapy administration process were designed using smartphone virtual reality to provide prelicensure students with an opportunity to learn procedural steps in a controlled, risk-free environment.

View Article and Find Full Text PDF

Purpose: The purpose of this systematic review was to consolidate and summarize available data comparing virtual reality perimetry (VRP) with standard automated perimetry (SAP) in adults with glaucoma. Understanding the utility and diagnostic performance of emerging VRP technology may expand access to visual field testing but requires evidence-based validation.

Methods: A systematic literature search was conducted in 3 databases (PubMed Central, Embase, and Cochrane Central Register of Controlled Trials) from the date of inception to 10/09/2024.

View Article and Find Full Text PDF

Background: With the increasing availability and use of digital tools such as virtual reality in medical education, there is a need to evaluate their impact on clinical performance and decision-making among healthcare professionals. The Trauma SimVR study is investigating the efficacy of virtual reality training in the context of traumatic in-hospital cardiac arrest.

Methods And Analysis: This study protocol (clinicaltrials.

View Article and Find Full Text PDF

A comparative analysis of perceptual noise in lateral and depth motion: Evidence from eye tracking.

J Vis

January 2025

Vision and Control of Action (VISCA) Group, Department of Cognition, Development and Psychology of Education, Institut de Neurociències, Universitat de Barcelona, Barcelona, Catalonia, Spain.

The characterization of how precisely we perceive visual speed has traditionally relied on psychophysical judgments in discrimination tasks. Such tasks are often considered laborious and susceptible to biases, particularly without the involvement of highly trained participants. Additionally, thresholds for motion-in-depth perception are frequently reported as higher compared to lateral motion, a discrepancy that contrasts with everyday visuomotor tasks.

View Article and Find Full Text PDF

A Microfabrication Technique for High-Performance Diffractive Optical Elements Tailored for Numerical Simulation.

Nanomaterials (Basel)

January 2025

Key Laboratory of All Optical Network and Advanced Telecommunication Network, Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing 100044, China.

Diffractive optical elements (DOEs) are specialized optical components that manipulate light through diffraction for various applications, including holography, spectroscopy, augmented reality (AR) and virtual reality (VR), and light detection and ranging (LiDAR). The performance of DOEs is highly determined by fabricated materials and fabrication methods, in addition to the numerical simulation design. This paper presents a microfabrication technique optimized for DOEs, enabling precise control of critical parameters, such as refractive index (RI) and thickness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!