Temperature Compensation Method for Mechanical Base of 3D-Structured Light Scanners.

Sensors (Basel)

Institute of Micromechanics and Photonics, Faculty of Mechatronics, Warsaw University of Technology, ul. Św. Andrzeja Boboli 8, 02-525 Warsaw, Poland.

Published: January 2020

The effect of temperature on three-dimensional (3D) structured light scanners is a very complex issue that, under some conditions, can lead to significant deterioration of performed measurements. In this paper, we present the results of several studies concerning the effect of temperature on the mechanical base of 3D-structured light scanners. We also propose a software compensation method suitable for implementation in any existing scanner. The most significant advantage of the described method is the fact that it does not require any specialized artifact or any additional equipment, nor access to the thermal chamber. It uses a simulation of mechanical base thermal deformations and a virtual 3D measurement environment that allows for conducting virtual measurements. The results from the verification experiments show that the developed method can extend the range of temperatures in which 3D-structured light scanners can perform valid measurements by more than six-fold.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7013603PMC
http://dx.doi.org/10.3390/s20020362DOI Listing

Publication Analysis

Top Keywords

light scanners
16
mechanical base
12
3d-structured light
12
compensation method
8
base 3d-structured
8
temperature compensation
4
method
4
method mechanical
4
light
4
scanners
4

Similar Publications

Background: Three-dimensional (3D) imaging enhances surgical planning and documentation in plastic surgery, but high costs limit accessibility. Mobile Light Detection and Ranging (LiDAR) technology offers a potential cost-effective alternative.

Objectives: To evaluate the accuracy and clinical utility of iPhone-based LiDAR scanning for breast measurements compared to traditional methods, and to establish standardized protocols for clinical implementation.

View Article and Find Full Text PDF

Background: Photon-counting detector (PCD) technology has the potential to reduce noise in computed tomography (CT). This study aimed to carry out a voxelwise noise characterization for a clinical PCD-CT scanner with a model-based iterative reconstruction algorithm (QIR).

Methods: Forty repeated axial acquisitions (tube voltage 120 kV, tube load 200 mAs, slice thickness 0.

View Article and Find Full Text PDF

Objective: This study aimed to compare the manufacturing accuracy of different printing techniques - Stereolithography (SLA), Digital Light Processing (DLP), and PolyJet-using digital dental models.

Methods: The study included cast models of 30 patients aged between 12 and 20 years. The selected models were scanned using an intraoral scanner, and surface topography format files were obtained.

View Article and Find Full Text PDF

Comparative evaluation of intraoral scanners and a spectrophotometer for percent correct shade identification in clinical dentistry.

Clin Oral Investig

January 2025

Center for Dental Medicine, Department of Operative Dentistry and Periodontology, Faculty of Medicine and Medical Center, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.

Objectives: The study aimed to assess the percent correct shade identification of four intraoral scanners (IOS) and a spectrophotometer, focusing on how reliably each device selects the correct tooth shade compared to a visual observer's selection. The research question addresses how much clinicians can trust the device-selected shade without visual verification.

Materials And Methods: Sixteen participants with natural, unrestored teeth were included.

View Article and Find Full Text PDF

Introduction: The chicken egg, with its compartments, is a widely used and popular animal model in experimental studies. This study aimed to quantify the volumes of the yolk/yolk sac, amniotic fluid, and chicken embryo using non-invasive ultra-high-field magnetic resonance imaging (UHF-MRI).

Materials And Methods: In total, 64 chicken eggs were examined using a 7 T UHF-MRI scanner, acquiring T2-weighted anatomical images of the entire egg from developmental day 1 to 16 (D1-D16).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?