A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Usability assessment of seven HIV self-test devices conducted with lay-users in Johannesburg, South Africa. | LitMetric

Introduction: The first 90 of the 90-90-90 initiative introduced by the World Health Organization(WHO) in 2015 requires 90% of people with HIV be aware of their status by 2020. In South Africa, conventional facility-based testing had reached 84.9% in 2018; innovative new methods, like HIV self-testing(HIVST) may close the testing gap. This study aimed to determine the usability of seven HIVST kits among untrained South Africans.

Methods: This cross-sectional study of 1400 adults in Johannesburg evaluated the usability of five blood fingerstick and two oral fluid HIVSTs, using WHO prequalification criteria, from June 2016 to June 2018. Participants were handed one kit, with no further information about the device or test procedure, and asked to perform the test in front of an observer. The observer used product-specific semi-structured questionnaires organized into a composite usability index(UI) using a HIVST process checklist, a contrived results interpretation and a post-test interview that expanded on participant experiences with the device and instructions-of-use(IFU). Participants were not tested themselves, but provided with contrived results to interpret.

Results: The average UI was 92.8%(84.2%-97.6%); the major difficulty was obtaining and transferring the specimen. Participants correctly interpreted 96.1% of the non-reactive/negative, 97.0% of the reactive/positive, 98.0% of the invalid and 79.9% of the weak positive results. Almost all participants(97.0%) stated they would visit a clinic or seek treatment for positive results; with negative results, half(50.6%) stated they should re-test in the next three months while one-third(36.1%) said they should condomize. Nearly all found the devices easy to use(96.6%), the IFUSs easy to understand(97.9%) and felt confident using the test unassisted(95.9%) but suggested improvements to packaging/IFUs to further increase usability; 19.9% preferred clinic-based testing to HIVST.

Conclusion: The UI and interpretation of results was high and in-line with previous usability studies, suggesting that these kits are appropriate for use in the general, untrained and unsupervised public.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6959591PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0227198PLOS

Publication Analysis

Top Keywords

south africa
8
usability
6
usability assessment
4
assessment hiv
4
hiv self-test
4
self-test devices
4
devices conducted
4
conducted lay-users
4
lay-users johannesburg
4
johannesburg south
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!