We present a setup for time-resolved X-ray diffraction based on a short pulse, laser-driven plasma X-ray source. The employed modular design provides high flexibility to adapt the setup to the specific requirements (e.g., X-ray optics and sample environment) of particular applications. The configuration discussed here has been optimized toward high angular/momentum resolution and uses K -radiation (4.51 keV) from a Ti wire-target in combination with a toroidally bent crystal for collection, monochromatization, and focusing of the emitted radiation. Ti-K photons per pulse with relative bandwidth are delivered to the sample at a repetition rate of 10 Hz. This allows for the high dynamic range (10) measurements of transient changes in the rocking curves of materials as for example induced by laser-triggered strain waves.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6941949 | PMC |
http://dx.doi.org/10.1063/1.5126316 | DOI Listing |
Phys Rev Lett
December 2024
Yale University, Department of Applied Physics and Physics, New Haven, Connecticut 06511, USA.
The selective number-dependent arbitrary phase gates form a powerful class of quantum gates, imparting arbitrarily chosen phases to the Fock states of a cavity. However, for short pulses, coherent errors limit the performance. Here, we demonstrate in theory and experiment that such errors can be completely suppressed, provided that the pulse times exceed a specific limit.
View Article and Find Full Text PDFJ Vis Exp
January 2025
Department of Biomedical Engineering, Washington University in St. Louis; Department of Obstetrics & Gynecology, Washington University in St. Louis;
For noninvasive light-based physiological monitoring, optimal wavelengths of individual tissue components can be identified using absorption spectroscopy. However, because of the lack of sensitivity of hardware at longer wavelengths, absorption spectroscopy has typically been applied for wavelengths in the visible (VIS) and near-infrared (NIR) range from 400 to 1,000 nm. Hardware advancements in the short-wave infrared (SWIR) range have enabled investigators to explore wavelengths in the ~1,000 nm to 3,000 nm range in which fall characteristic absorption peaks for lipid, protein, and water.
View Article and Find Full Text PDFMol Neurobiol
January 2025
Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200433, China.
Weightlessness usually causes disruption of the gut microbiota and impairs cognitive function. There is a close connection between gut microbiota and neurological diseases. Low-intensity pulsed ultrasound (LIPUS) has a beneficial effect on reducing intestinal inflammation.
View Article and Find Full Text PDFHigh-resolution optical diagnostics in the short wavelength infrared (SWIR II) region have gained significant attention in medical research, showing great potential for tissue spectroscopy and visualization due to the region's low water absorption and scattering coefficients. However, high-beam-quality sources covering an entire spectral range are limited. This paper presents the development of a femtosecond Cr:ZnSe laser with a 2.
View Article and Find Full Text PDFUltrashort pulse sources are complex and resource-intensive. To reduce overhead and simplify operations, we had previously developed a method to deliver ultra-short pulses through fiber-optic links to multiple locations and to characterize them remotely using a compact detector module. We created a pulse pair with varying delays at the central location using a pulse shaper before launching them into the fiber links and measured the first and second-order autocorrelations at the satellite location.