Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A reverse guidewire technique along with double lumen catheter has become a standard technique for extremely angulated bifurcation lesions. A-72-year-old male underwent coronary angiography, which revealed a severe stenosis of the left anterior descending artery with an extremely angulated diagonal branch. We introduced the Crusade (Kaneka, Osaka, Japan) accompanied with the reversed guidewire to the lesion, but the Crusade with the reversed guidewire could not cross the lesion. We kept the Crusade at the just proximal to the stenosis, and advanced the only reversed guidewire to the lesion. The reversed guidewire successfully crossed the lesion, and then we pulled back the reversed guidewire to lead the reversed guidewire's tip into the diagonal branch retrogradely. In this modified reverse guidewire technique, the Crusade does not need to cross the lesion, but needs to bring the reversed guidewire at the just proximal of the lesion. Because the profile of the reversed guidewire alone is smaller than that of the Crusade accompanied with the reversed guidewire, the reversed guidewire alone has greater chance to cross the severe stenosis. Our modification may increase the success rate of the reverse guidewire technique, and expand the indication of this technique. < In a reverse guidewire technique, if there is a severe stenosis at just proximal of the bifurcation lesion, it may be difficult to cross the double lumen catheter with a reversed guidewire beyond the bifurcation lesion, because the profile of the double lumen catheter accompanied with a reversed guidewire is much larger than the double lumen catheter or the reversed guidewire alone. We modified reverse guidewire technique, which may increase the success rate of the reverse guidewire technique.>.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6951300 | PMC |
http://dx.doi.org/10.1016/j.jccase.2019.09.005 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!