AI Article Synopsis

  • * A study was conducted on dialysis patients at a single hospital to develop a new technique for placing tunnelled cuffed catheters (TCC) without fluoroscopic guidance, using anatomical landmarks and ultrasound measurements instead.
  • * Out of 209 catheters placed, there was a high success rate of 97.1%, especially in the right internal jugular vein, demonstrating that the new method is both safe and effective in resource-limited settings.

Article Abstract

Background: Chronic kidney disease is a growing disease with high morbidity and mortality. Haemodialysis remains the most common option available for all those not planning for renal transplantation. Vascular access is the most important aspect of haemodialysis. Though not recommended but central venous catheters remain the most common vascular access in starters on haemodialysis. There is a growing trend towards placement of tunnelled cuffed catheters (TCC). Tunnelled cuffed catheters placement requires fluoroscopic guidance which is not available in all centres. The rationale of this study was to describe safety and accuracy of a catheter placement technique not dependent on fluoroscopic guidance for resource limited settings.

Methods: Dialysis dependent patients of a single hospital without long term vascular access were selected over a period of 15 months after getting informed written consent. A new technique was described in which depth of catheter was estimated by superficial anatomical and ultrasound guided measurements for TCC placement which were checked by conventional chest radiography post procedure.

Results: A total of 209 catheters were placed over a period of 15 months, 189 males and 30 females. Various sites were used predominantly right Internal jugular vein (IJV) (85.6%). Overall success rate was 97.1% (98.3% males, 90% females, p=0.08). Right IJV was successful 98.9%, left IJV 87.5% (p<0.001). Multiple thrombosed/stenosed veins were associated with higher failure rate (p<0.001).

Conclusions: Tunnelled cuffed catheters can be placed successfully and safely in right IJV under ultrasound guidance using anatomical landmark measurement technique without fluoroscopic guidance.

Download full-text PDF

Source

Publication Analysis

Top Keywords

tunnelled cuffed
12
fluoroscopic guidance
12
vascular access
12
ultrasound guided
8
catheter placement
8
cuffed catheters
8
period months
8
placement
5
guided tunnelled
4
cuffed catheter
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!