Purpose: To compare the response to cyclical loading and ultimate pull-out strength of threaded suture anchor with and without calcium phosphate bone void filler augmentation in a polyurethane foam block model and in vitro proximal humerus cadaveric model.

Methods: This controlled biomechanical study consisted of 2 parts: (1) preliminary polyurethane foam block model, and (2) in vitro cadaveric humeri model. The preliminary foam block model intended to mimic osteoporotic bone using a 0.12 g/mL foam material. Half of the foam block models were first filled with injectable calcium phosphate bone substitute material (CP-BSM), whereas the other half were not augmented with CP-BSM. Each specimen was then instrumented with a threaded suture anchor. The same technique and process was performed in a matched cadaveric humeri model. Testing then consisted of a stepwise, increasing axial load protocol for a total of 40 cycles. If the anchor remained intact after cyclic loading, the repair was loaded to failure. The number of completed cycles, failure load, and failure modes were compared between groups.

Results: Average pull-out strength for suture anchor with CP-BSM in the osteoporotic foam block model was significantly higher at 332.68 N ± 47.61 compared with the average pull-out strength of suture anchor without CP-BSM at 144.38 N ± 14.58 (P = .005). In the matched cadaveric humeri model, average pull-out strength for suture anchor with CP-BSM was significantly higher at 274.07 N ± 102.07 compared with the average pull-out strength of suture anchor without CP-BSM at 138.53 N ± 109.87 (P = .029).

Conclusions: In this time zero, biomechanical study, augmentation of osteoporotic foam block and cadaveric bone with calcium phosphate bone substitute material significantly increases pull-out strength of threaded suture anchors.

Clinical Relevance: Considering concerns about suture anchor pull-out from osteoporotic bone, augmentation with calcium phosphate bone substitute material increases load to failure resistance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2019.12.003DOI Listing

Publication Analysis

Top Keywords

suture anchor
32
pull-out strength
24
foam block
24
calcium phosphate
20
phosphate bone
20
threaded suture
16
block model
16
average pull-out
16
strength suture
16
anchor cp-bsm
16

Similar Publications

The deltoid ligament (medial collateral ligament) and the syndesmosis (a composite ligamentous structure at the distal tibiofibular junction) are critical for maintaining ankle stability. In cases of high-energy ankle fractures, these structures are often injured simultaneously, leading to instability and potential long-term complications such as post-traumatic arthritis. This review aims to explore advancements in minimally invasive techniques for the treatment of combined deltoid ligament and syndesmosis injuries, with a focus on optimizing surgical outcomes and reducing patient morbidity.

View Article and Find Full Text PDF

This prospective, observational cohort study compares the clinical and radiographic outcomes of the modified Weaver and Dunn (WD) technique with the newer, anatomical double-button plus tendon allograft technique (DB), and the suture anchor repair plus tendon allograft (SA). The study cohort includes 53 patients, who underwent surgery for acromioclavicular joint (ACJ) dislocation Rockwood type 3, 4 and 5. Patient-reported outcome scores and clinical results, including Disabilities of the Arm, Shoulder and Hand (DASH), the Subjective Shoulder Value (SSV), the Visual Analogue Scale (VAS) and the Constant score (CS) results as well as loss of reduction rates on plain radiographs were compared.

View Article and Find Full Text PDF

Therapeutic effect of titanium locking plate combined with suture anchor repair in proximal humeral fractures.

Pak J Med Sci

January 2025

Zhenfeng Huang Department of Orthopedic Trauma, Wuhan Fourth Hospital, Wuhan, Hubei Province 430000, P.R. China.

Objective: To explore the therapeutic effect of titanium locking plate combined with suture anchor (SA) repair in the treatment of proximal humeral fractures (PHF).

Methods: This retrospective study was conducted by analyzing the clinical data of 113 patients with PHF admitted to Wuhan Fourth Hospital from March 2021 to October 2023. Among them, 55 patients underwent open reduction and internal fixation (OR/IF) using titanium locking plate (OR/IF group), and 58 patients underwent surgery with titanium locking plate combined with SA (SA group).

View Article and Find Full Text PDF

Objective: The purpose of this study was to investigate the timing and mode of failure of metallic screw-type suture anchors used to attach artificial tendons to bone in an New Zealand White rabbit model.

Study Design: Metal suture anchors with braided composite sutures of varying sizes (United States Pharmacopeia (USP) size 1, 2, or 5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 female New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement,  = 8), or four/five weeks after (delayed replacement,  = 4) resection of the biological tendon.

View Article and Find Full Text PDF

Introduction: More extensive and cohesive studies on quadriceps tendon rupture (QTR) repair surgery are required to guide effective treatment strategies. Therefore, in this study, we aimed to identify predictors of subjective functional recovery following QTR repair surgery.

Materials And Methods: This multicentre retrospective cohort study enrolled 191 adults (age ≥ 18 years) who underwent surgical unilateral QTR repair (2010-2022) and had ≥ 1-year postoperative follow-up at three trauma centres in Germany.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!