A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Trueness evaluation and verification of inter-assay agreement of serum folate measuring systems. | LitMetric

Background Definitive data to establish if the use of the WHO International Standard (IS) 03/178 as a common calibrator of commercial measuring systems (MSs) has improved the harmonization of serum total folate (tFOL) measurements to a clinically suitable level are lacking. Here, we report the results of an intercomparison study aimed to verify if the current inter-assay variability is acceptable for clinical application of tFOL testing. Methods After confirming their commutability, the IS 03/178 and National Institute for Standards and Technology SRM 3949 L1 were used for evaluating the correctness of traceability implementation by manufacturers and the MSs trueness, respectively. The inter-assay agreement was verified using 20 patient pools. The measurement uncertainty (U) of tFOL measurements on clinical samples was also estimated. An outcome-based model for defining desirable performance specifications for bias and imprecision for serum tFOL measurements was applied. Results The majority of evaluated MSs overestimated the WHO IS value of +5% or more with the risk to produce an unacceptably high number of false-negative results in clinical practice. The mean inter-assay CV on all pools and on those with tFOL values >3.0 μg/L (n = 15) was 12.5% and 7.1%, respectively. In neither case the goal of 3.0% was fulfilled. The residual bias resulted in an excessive U of tFOL measurement on clinical samples. Conclusions The implementation of traceability of tFOL MSs to the WHO IS 03/178 is currently inadequate, resulting in an inter-assay variability that does not permit the use of a common threshold for detecting folate deficiency.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2019-0928DOI Listing

Publication Analysis

Top Keywords

tfol measurements
12
inter-assay agreement
8
measuring systems
8
inter-assay variability
8
clinical samples
8
tfol
7
inter-assay
5
trueness evaluation
4
evaluation verification
4
verification inter-assay
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!