A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cu-DOTATATE PET/CT for Imaging Patients with Known or Suspected Somatostatin Receptor-Positive Neuroendocrine Tumors: Results of the First U.S. Prospective, Reader-Masked Clinical Trial. | LitMetric

Studies demonstrate that the investigational Cu-DOTATATE radiopharmaceutical may provide diagnostic and logistical benefits over available imaging agents for patients with somatostatin receptor (SSTR)-positive neuroendocrine tumors (NETs). Accordingly, we aimed to prospectively determine the lowest dose of Cu-DOTATATE that facilitates diagnostic-quality scans and evaluated the diagnostic performance and safety in a phase III study of patients with SSTR-expressing NETs. A dose-ranging study was conducted on 12 patients divided into 3 dose groups (111 MBq [3.0 mCi], 148 MBq [4.0 mCi], and 185 MBq [5.0 mCi] ± 10%) to determine the lowest dose of Cu-DOTATATE that produced diagnostic-quality PET/CT images. Using the Cu-DOTATATE dose identified in the dose-ranging study, 3 independent nuclear medicine physicians who were masked to all clinical information read PET/CT scans from 21 healthy volunteers and 42 NET-positive patients to determine those with disease or no disease, as well as those with localized versus metastatic status. Masked-reader evaluations were compared with a patient-specific standard of truth, which was established by an independent oncologist who used all previously available pathology, clinical, and conventional imaging data. Diagnostic performance calculated for Cu-DOTATATE included sensitivity, specificity, negative predictive value, positive predictive value, and accuracy. Inter- and intrareader reliability, as well as ability to differentiate between localized and metastatic disease, was also determined. Adverse events were recorded from Cu-DOTATATE injection through 48 h after injection. The dose-ranging study identified 148 MBq (4.0 mCi) as the optimal dose to obtain diagnostic-quality PET/CT images. After database lock, diagnostic performance from an initial majority read of the 3 independent readers showed a significant 90.9% sensitivity ( = 0.0042) and 96.6% specificity ( < 0.0001) for detecting NETs, which translated to a 100.0% sensitivity and 96.8% specificity after correcting for an initial standard-of-truth misread. Excellent inter- and intrareader reliability, as well as ability to distinguish between localized and metastatic disease, was also noted. No adverse events were related to Cu-DOTATATE, and no serious adverse events were observed. Cu-DOTATATE PET/CT is a safe imaging technique that provides high-quality and accurate images at a dose of 148 MBq (4.0 mCi) for the detection of somatostatin-expressing NETs.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.119.236091DOI Listing

Publication Analysis

Top Keywords

diagnostic performance
12
dose-ranging study
12
148 mbq
12
adverse events
12
cu-dotatate
9
cu-dotatate pet/ct
8
neuroendocrine tumors
8
determine lowest
8
lowest dose
8
dose cu-dotatate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!