Accuracy of clinical suspicion of growth restriction at term despite a normal growth ultrasound: A retrospective cohort study.

Aust N Z J Obstet Gynaecol

Translational Obstetrics Group, Department of Obstetrics and Gynaecology, Mercy Hospital for Women, University of Melbourne, Melbourne, Victoria, Australia.

Published: August 2020

Background: Small for gestational age (SGA) is a major determinant of poor perinatal outcome. Detecting SGA at term using ultrasound is challenging and we often plan birth based on clinical assessment.

Aims: To determine the incidence of SGA infants with birthweight <10th centile among women undergoing planned birth at term for suspected SGA despite a normal estimated fetal weight (EFW) on ultrasound at 35-37 weeks.

Materials And Methods: We performed a retrospective study including all women with a fetal growth ultrasound at ≥35 weeks reporting an EFW ≥ 10th centile (appropriate for gestational age, AGA) who subsequently had an induction of labour or caesarean birth at ≥37 weeks due to ongoing clinical suspicion of SGA between 2012-2014. The primary outcome was the incidence of SGA newborns using customised centiles.

Results: There were 532 women who had a planned birth for clinical suspicion of SGA during the study period. Of these, 205 (38.5%) had an AGA fetus on ultrasound ≥35 weeks but were subsequently delivered because of a persisting clinical suspicion of SGA on abdominal assessment. Sixty-eight percent (n = 139/205) delivered an SGA infant. Furthermore, almost half of these SGA infants (47.5%) had a birthweight <3rd centile. Neonatal outcomes were worse for the SGA infants, with 15.1% (n = 21/205) requiring special care nursery compared to 1.5% (n = 1/205) of those AGA at birth.

Conclusions: A reassuring ultrasound with EFW ≥10th centile in the late third trimester should not override clinical concerns of impaired fetal growth at term.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ajo.13111DOI Listing

Publication Analysis

Top Keywords

accuracy clinical
4
clinical suspicion
4
suspicion growth
4
growth restriction
4
restriction term
4
term despite
4
despite normal
4
normal growth
4
growth ultrasound
4
ultrasound retrospective
4

Similar Publications

Objective: The first objective is to develop a nuchal thickness reference chart. The second objective is to compare rule-based algorithms and machine learning models in predicting small-for-gestational-age infants.

Method: This retrospective study involved singleton pregnancies at University Malaya Medical Centre, Malaysia, developed a nuchal thickness chart and evaluated its predictive value for small-for-gestational-age using Malaysian and Singapore cohorts.

View Article and Find Full Text PDF

Purpose: Patients with advanced non-small cell lung cancer (NSCLC) have varying responses to immunotherapy, but there are no reliable, accepted biomarkers to accurately predict its therapeutic efficacy. The present study aimed to construct individualized models through automatic machine learning (autoML) to predict the efficacy of immunotherapy in patients with inoperable advanced NSCLC.

Methods: A total of 63 eligible participants were included and randomized into training and validation groups.

View Article and Find Full Text PDF

This study aims to identify the factors influencing decannulation in patients with stroke who underwent tracheostomy during the early subacute phase. A retrospective analysis was conducted on 219 patients with stroke who underwent a tracheostomy at a tertiary hospital between January 2020 and December 2023. Among them, there were 155 males and 64 females.

View Article and Find Full Text PDF

Objective: To evaluate the diagnostic accuracy of 18F-FDG-PET/CT compared to conventional imaging modalities (CIM) to detect recurrence of primary salivary gland cancers (SGCs).

Data Sources: Review performed on December 26, 2024, using Embase, CINHAL, MEDLINE, and PubMed.

Review Methods: Two blinded reviewers selected studies reporting diagnostic accuracy of PET/CT in identifying locoregional recurrence and/or metastasis in patients with SGCs.

View Article and Find Full Text PDF

Background: During the course of the past two decades, head-mounted augmented reality surgical navigation (HMARSN) systems have been increasingly employed in a variety of surgical specialties as a result of both advancements in augmented reality-related technologies and surgeons' desires to overcome some drawbacks inherent to conventional surgical navigation systems. In the present time, most experimental HMARSN systems adopt overlain display (OD) that overlay virtual models and planned routes of surgical tools on corresponding physical tissues, organs, lesions, and so forth, in a surgical field so as to provide surgeons with an intuitive and direct view to gain better hand-eye coordination as well as avoid attention shift and loss of sight (LOS), among other benefits during procedures. Yet, its system accuracy, which is the most crucial performance indicator of any surgical navigation system, is difficult to ascertain because it is highly subjective and user-dependent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!