Phase-Contrast MRI: Physics, Techniques, and Clinical Applications.

Radiographics

From the Department of Diagnostic Radiology, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140.

Published: February 2021

With phase-contrast imaging, the MRI signal is used to visualize and quantify velocity. This imaging modality relies on phase data, which are intrinsic to all MRI signals. With use of bipolar gradients, degrees of phase shift are encoded and in turn correlated directly with the velocity of protons. The acquisition of diagnostic-quality images requires selection of the correct imaging plane to ensure accurate measurement and selection of the encoding velocity and thus prevent aliasing and achieve the highest signal-to-noise ratio. Multiple applications of phase-contrast imaging are actively used in clinical practice. One of the most common clinical uses is in cardiac valvular flow imaging, at which the data are used to assess the severity of valvular disease and quantify the shunt fraction. In neurologic imaging, phase-contrast imaging can be used to measure the flow of cerebrospinal fluid. This measurement can aid in the diagnosis and direct management of normal pressure hydrocephalus or be used to evaluate the severity of stenosis, such as that in Chiari I malformations. At vascular analysis, phase-contrast imaging can be used to visualize arterial and venous flow, and this application is used most commonly in the brain. Three-dimensional imaging can yield highly detailed flow data in a technique referred to as four-dimensional flow. A more recently identified application is in MR elastography. Shear waves created by using an impulse device can be velocity encoded, and this velocity is directly proportional to the stiffness of the organ, or the shear modulus. This imaging modality is most commonly used in the liver for evaluation of cirrhosis and steatosis, although research on the assessment of other organs is being performed. Phase-contrast imaging is an important tool in the arsenal of MRI examinations and has many applications. Proper use of phase-contrast imaging requires an understanding of the many practical and technical factors and unique physics principles underlying the technique.RSNA, 2020.

Download full-text PDF

Source
http://dx.doi.org/10.1148/rg.2020190039DOI Listing

Publication Analysis

Top Keywords

phase-contrast imaging
24
imaging
12
applications phase-contrast
8
imaging modality
8
phase-contrast
7
velocity
5
flow
5
phase-contrast mri
4
mri physics
4
physics techniques
4

Similar Publications

The meniscus effect in cell culture vessels limits the observable areas with phase contrast microscopy. For meniscus effect compensation in microtiter plates (MTPs), we present a method using an LCD to replace the fixed condenser annulus, which enables adaptive annulus shifting based on image analysis. This approach led to an increase in phase contrast area by a factor of 8.

View Article and Find Full Text PDF

Phase-contrast micro-tomography ([Formula: see text]CT) with synchrotron radiation can aid in the differentiation of subtle density variations in weakly absorbing soft tissue specimens. Modulation-based imaging (MBI) extracts phase information from the distortion of reference patterns, generated by periodic or randomly structured wavefront markers (e.g.

View Article and Find Full Text PDF

Background: Paramagnetic rim lesions (PRLs) are a magnetic resonance imaging (MRI) marker of compartmentalized intraparenchymal inflammation.

Objectives: The primary objective was to investigate clinical, demographic, and MRI factors that may be predictive of the future formation of PRL.

Methods: This is a retrospective analysis of longitudinal data.

View Article and Find Full Text PDF

Transmission electron microscopy, especially at cryogenic temperature, is largely used for studying biological macromolecular complexes. A main difficulty of TEM imaging of biological samples is the weak amplitude contrasts due to electron diffusion on light elements that compose biological organisms. Achieving high-resolution reconstructions implies therefore the acquisition of a huge number of TEM micrographs followed by a time-consuming image analysis.

View Article and Find Full Text PDF

Introduction: Reports of pseudoaneurysms associated with biliary self-expandable metallic stent (SEMS) placement have been increasing. Recently, cases of hepatic pseudoaneurysm rupture caused by double pigtail plastic stents (DPS) have also been reported. The symptoms of pseudoaneurysms are often non-specific, and many cases are diagnosed only after rupture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!