Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Percutaneous transluminal angioplasty is a well-known treatment for arteriovenous fistula stenosis. Balloon rupture during endovascular procedures is a rare but possible complication. The bursting balloon itself does not cause a serious problem, but it can occasionally cause entrapment, especially in case of breakdown of the balloon catheter tip. Here, we present four cases of balloon rupture during angioplasty in the hemodialysis circuit. In three cases, the ruptured balloon catheter was removed by cutdown of access conduit, while in one case, tip of ruptured balloon catheter was migrated into the pulmonary artery and was removed surgically. The operator must attempt to reduce the risk of balloon rupture by gradually expanding the balloons under bursting pressure. If the balloon bursts, it should not be removed excessively and attempt should be made to remove it using endovascular techniques. Surgical removal is considered after careful evaluation of the condition of the balloon and vessel.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6941773 | PMC |
http://dx.doi.org/10.5758/vsi.2019.35.4.245 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!