Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report.

Imaging Sci Dent

Department of Oral and Maxillofacial Radiology, Graduate School, Kyung Hee University, Seoul, Korea.

Published: December 2019

Purpose: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases.

Materials And Methods: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow.

Results: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan.

Conclusion: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6941833PMC
http://dx.doi.org/10.5624/isd.2019.49.4.301DOI Listing

Publication Analysis

Top Keywords

power doppler
20
increased blood
12
blood flow
12
doppler ultrasound
12
doppler ultrasound-guided
8
ultrasound-guided sialography
8
sialography phenomenon
8
phenomenon increased
8
salivary gland
8
main duct
8

Similar Publications

The maternal body mass index and first-trimester placental (vascular) development.

Placenta

December 2024

Department of Obstetrics and Gynecology, Erasmus MC, University Medical Center, Rotterdam, the Netherlands. Electronic address:

Background: Maternal obesity is associated with maternal complications, including hypertensive disorders of pregnancy (HDP), and related fetal complications, such as fetal growth restriction. During pregnancy, the placenta is one of the key regulators of embryonic and fetal growth. Previous studies mainly investigated placental growth by measuring postpartum placental weight.

View Article and Find Full Text PDF

The predictive value of anti-IFI16 antibodies for the development or persistence of digital ulcers in systemic sclerosis.

Clin Rheumatol

January 2025

Department of Rheumatology, Huashan Hospital, Fudan University, No.12 Wulumuqi Zhong Road, Shanghai, 200040, China.

To evaluate the association of anti-IFI16 antibodies with peripheral vasculopathy and the predictive value of anti-IFI16 antibodies for the development or persistence of digital ulcers (DPDU) in SSc. A total of 42 SSc patients and 42 age- and sex-matched healthy controls were enrolled. Anti-IFI16 antibodies were examined by ELISA.

View Article and Find Full Text PDF

Usefulness of Aortic Valve Calcification in Patients With Low-Flow Aortic Stenosis.

Circ Cardiovasc Imaging

January 2025

Department of Cardiology, Odense University Hospital, Denmark (N.S.B.M., J.S.D., M.A., A.H., R.C.-S., J.E.M., K.A.Ø., M.-A.C.).

Background: Aortic valve calcification (AVC) has been shown to be a powerful assessment of aortic stenosis (AS) severity and a predictor of adverse outcomes. However, its accuracy in patients with low-flow AS has not yet been proven. The objective of the study was to assess the predictive value of AVC in patients with classical low-flow (CLF, that is, low-flow reduced left ventricular ejection fraction) or paradoxical low-flow (PLF, that is, low-flow preserved left ventricular ejection fraction) AS.

View Article and Find Full Text PDF

UAV Trajectory Control and Power Optimization for Low-Latency C-V2X Communications in a Federated Learning Environment.

Sensors (Basel)

December 2024

Department of Electrical, Computer and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON M5B2K3, Canada.

Unmanned aerial vehicle (UAV)-enabled vehicular communications in the sixth generation (6G) are characterized by line-of-sight (LoS) and dynamically varying channel conditions. However, the presence of obstacles in the LoS path leads to shadowed fading environments. In UAV-assisted cellular vehicle-to-everything (C-V2X) communication, vehicle and UAV mobility and shadowing adversely impact latency and throughput.

View Article and Find Full Text PDF

Objective: The study aimed to explore the utility of contrast-enhanced ultrasound (CEUS) as a tool for detecting minimal inflammation in rheumatoid arthritis (RA) patients in sustained remission (SR) and to correlate the findings with Disease Activity Score 28 (DAS28) status scores and various ultrasound (US) scores.

Patients And Methods: Thirty RA patients in SR (minimum 6 months), 12 with active disease, and 10 healthy controls were included. Clinical evaluations and US assessments were performed, including grayscale US (GSUS), power Doppler US (PDUS), and Global OMERACT-EULAR Synovitis Score (GLOESS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!