Accuracy and Reliability of the Visual Assessment of Patellar Tracking.

Am J Sports Med

Department of Orthopaedic Surgery, The Johns Hopkins Hospital, Baltimore, Maryland, USA.

Published: February 2020

Background: Abnormal patellar tracking is described as a "J-sign" when the patella exhibits excessive lateral displacement during active knee extension.

Purpose: To determine (1) the accuracy and reliability of the visual assessment of patellar tracking when viewed by surgeons with patellofemoral expertise and (2) whether surgeon experience (in years) correlates with the ability to accurately identify the presence and severity of patellar maltracking.

Study Design: Cohort study (diagnosis); Level of evidence, 2.

Methods: Using a web-based assessment, 32 orthopaedic surgeon members of the International Patellofemoral Study Group determined the presence or absence of maltracking (≥2 quadrants of lateral translation) in 10 single-knee videos of patients with patellar instability during active knee extension (qualitative analysis). Surgeons then graded patellar tracking in 20 single-knee videos as follows: 0 (<1 patellar quadrant of lateral translation), 1 (1 to <2 quadrants), 2 (2 to <3 quadrants), or 3 (≥3 quadrants) (quantitative analysis). Responses were compared with a previously described grading system using patellar bisect offset measured with 4-dimensional computed tomography. We evaluated the association between number of years of surgeon experience and the ability to correctly identify and grade patellar tracking. A total of 22 surgeons repeated the survey 3 months later, and their answers were matched to the first survey, allowing for assessment of intraobserver reliability.

Results: In the qualitative analysis, surgeons correctly identified videos as showing patellar maltracking 68% of the time (κ = 0.45). In the quantitative analysis, 53%, 51%, 48%, and 68% of surgeons correctly identified maltracking of grades 3, 2, 1, and 0, respectively (κ = 0.42). Surgeon experience did not correlate with ability to identify the presence ( = .59) or grade ( = .35) of patellar maltracking. Respondent answers from the second survey demonstrated inadequate intraobserver reliability (κ = 0.48).

Conclusion: Using visual assessment alone, surgeons correctly identified patellar maltracking in approximately two-thirds of videos and correctly graded patellar maltracking in half. Inter- and intraobserver reliability were inadequate to support the use of visual assessment alone for detecting the presence or grade of patellar maltracking. Surgeon experience did not correlate with ability to identify the presence or grade of patellar maltracking.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0363546519895246DOI Listing

Publication Analysis

Top Keywords

patellar tracking
16
accuracy reliability
8
reliability visual
8
visual assessment
8
assessment patellar
8
active knee
8
single-knee videos
8
patellar
6
tracking
4
tracking background
4

Similar Publications

Case Report of a Traumatic Arthrotomy of the Knee Diagnosed by Ultrasound.

Wilderness Environ Med

January 2025

Department of Emergency Medicine, Denver Health Hospital, Denver, CO.

In this case report we describe evaluating a patient for a traumatic knee arthrotomy using ultrasound in a resource-limited medical clinic at the base of a ski area. A 23-y-old female presented with a laceration superior to the patella of the left leg. On examination, the wound tracked deep, and providers had concern for traumatic arthrotomy.

View Article and Find Full Text PDF

Aim The primary objective of the study was to evaluate the mid-term implant survivability, rate of revisions, and clinical and functional outcomes following patella resurfacing during total knee arthroplasty (TKA) utilizing posterior stabilized (PS) total knee system (TKS). Methods A prospective, single-arm, multi-center, post-marketing surveillance encompassed patients with end-stage primary knee osteoarthritis (OA) or inflammatory arthritis. The time points of the study included baseline, six weeks, six months, one year, and three years post-operatively.

View Article and Find Full Text PDF

Purpose: To propose a new sign of patellar maltracking in recurrent patellar dislocation (RPD) and compare the differences in lower limb rotational and bony structural abnormalities among the different signs.

Patients And Methods: A retrospective study included 279 patients (mean age: 22 years; female: 81%) who underwent primary surgery for RPD over the past 4 years was performed. The patients were grouped based on the characteristics of patellar tracking: low-, moderate- and high-grade J-sign.

View Article and Find Full Text PDF

: Abnormalities in patellar tracking, often overlooked in surgical planning, have been identified as a contributing factor to total knee arthroplasty (TKA) complications, including anterior knee pain, patellar subluxation, and dislocation. This study aims to evaluate the repeatability of a novel intraoperative setup for assessing patellofemoral kinematics and its interaction with prosthesis design and positioning during surgery. This setup may support personalized alignment techniques in TKA, potentially improving surgical outcomes.

View Article and Find Full Text PDF

Current status of bicompartmental arthroplasty.

Arthroplasty

January 2025

Department of Orthopedics, School of Medicine, Renji Hospital, Shanghai Jiao Tong University, Shanghai, 201112, China.

Background: Bicompartmental arthroplasty (BCA) serves as a less invasive alternative to total knee arthroplasty. This review aims to present the current status of BCA. BODY: Recent literature on BCA was reviewed and synthesized from the perspectives of function, radiological assessment, patient satisfaction, survival rate, patellar tracking, satisfaction survey, and revision rate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!