Objective: The aim of the study was to evaluate the effect of a single-capsule 17β-estradiol/progesterone (E2/P4), TX-001HR, on endometrial safety, to report on amenorrhea and bleeding patterns of users, and to identify predictors of amenorrhea.

Methods: The REPLENISH trial (NCT01942668) evaluated use of TX-001HR in menopausal women (40-65 y) with vasomotor symptoms (VMS) and a uterus. Women were randomized to daily E2/P4 (mg/mg: 1/100, 0.5/100, 0.5/50, or 0.25/50), or placebo for 12 months. Incidence rate of endometrial hyperplasia was calculated from endometrial biopsies conducted at screening and study completion. Women reported bleeding and spotting in daily diaries. The number of bleeding and/or spotting days and the proportion of women with no bleeding or amenorrhea were compared between treatment and placebo using the Fisher exact test. Predictors of cumulative amenorrhea were assessed by univariate analyses.

Results: Women (n = 1,835) who took at least one study dose comprised the safety population; 1,255 had baseline and 12-month biopsies and comprised the endometrial safety population. Incidence of endometrial hyperplasia was ≤0.36% with any dose of TX-001HR after 1 year of use (one-sided upper 95% confidence interval ≤4%). Cumulative amenorrhea (no bleeding/spotting) rates increased over time and were relatively high from cycle 1 to 13 with TX-001HR (56%-73%; placebo 79%; P < 0.05 except with 0.25/50 dose). Few vaginal bleeding adverse events (1.0%-4.6% TX-001HR vs 0.7% placebo) were reported and discontinuations due to bleeding were low (0.4%-1.4% vs 0%). Cumulative amenorrhea was significantly more frequent in older women, those further from their last menstrual period, and those with lower baseline E2 concentrations (all; P < 0.01).

Conclusions: All doses of TX-001HR provided endometrial protection and were associated with an improved bleeding profile over time; older age, further last menstrual period, or lower baseline E2 may predict amenorrhea with TX-001HR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7147409PMC
http://dx.doi.org/10.1097/GME.0000000000001480DOI Listing

Publication Analysis

Top Keywords

endometrial safety
12
endometrial hyperplasia
8
cumulative amenorrhea
8
safety population
8
endometrial
6
bleeding
5
tx-001hr
5
women
5
safety bleeding
4
bleeding profile
4

Similar Publications

Background: A surgical robot with force feedback can guarantee precise and gentle manipulation for endometrial repair, ensuring the effectiveness and safety of the manipulation. However, the design of force sensors for surgical robots is challenging due to the limited anatomical space and the requirement for continuous rotation.

Methods: This paper presents a novel force-sensing surgical instrument for endometrial repair, including an inner scraping instrument and an outer force sensing sheath.

View Article and Find Full Text PDF

Background: To date, 11 DNA polymerase epsilon (POLE) pathogenic variants have been declared "hotspot" mutations. Patients with endometrial cancer (EC) characterized by POLE hotspot mutations (POLEmut) have exceptional survival outcomes. Whereas international guidelines encourage deescalation of adjuvant treatment in early-stage POLEmut EC, data regarding safety in POLEmut patients with unfavorable characteristics are still under investigation.

View Article and Find Full Text PDF

Overexpression of the gonadotropin-releasing hormone receptor (GnRH-R) plays a vital role in the advancement of reproductive malignancies such as ovarian, endometrial, and prostate cancer. Peptidomimetic GnRH antagonists are a substantial therapeutic development, providing fast and reversible suppression of gonadotropins by directly blocking GnRH-R. Unlike typical GnRH agonists, these antagonists prevent the early hormonal flare, have a faster onset of action, and have a lower risk of cardiovascular problems.

View Article and Find Full Text PDF

Sentinel lymph node (SLN) detection has been widely investigated in recent years as a part of the surgical staging of women with endometrial cancer (EC), gradually overtaking lymphadenectomy (LND) in this respect. In this study, thirty EC patients, assumed as stage I, were investigated using superparamagnetic iron oxide (SPIO) as a tracer for SLN detection followed by LND. The endpoints of this research were the proportion of successful SLN detection, the average number of SLNs per patient, the percentage of bilaterally detected SLNs, and the proportion of metastatic SLNs.

View Article and Find Full Text PDF

: Autologous platelet-rich plasma (PRP) transfusions are a relatively new treatment method used in different fields of medicine, including the field of reproductive medicine. One of the applications of these concentrated platelet infusions is the treatment of endometrial receptivity, which is a key factor for embryo implantation. There are implications that PRP infusions can lead to increased endometrial thickness, endometrial receptivity, and significantly elevated clinical pregnancy rates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!