This study aims to clarify some of the issues associated with the reliable measurement of muscle thickness on ultrasonographic images of the musculoskeletal system, namely the repeatability of measurements in different time frames, the effect of body side selection, and the effect of scan orientation. Ultrasound scans were performed on muscles associated with essential daily activities: geniohyoid, masseter, anterior arm muscles, rectus femoris, vastus intermedius, tibialis anterior, and gastrocnemius. Measurements of the muscle thickness were performed and repeated after 1, 6, and 24 h, on both dominant and nondominant side, using both transverse and longitudinal scans. Thirteen healthy volunteers (eight males and five females, mean age = 24 years, SD = 2.86, range = 19-29) were included. The intraclass correlation coefficient (ICC) was calculated between the baseline and the 1-, 6-, and 24-h interval, using a two-way mixed model of absolute agreement. The ICC ranged from 0.295 for the longitudinal scan of the left masseter muscle in the 6-h interval to 0.991 for the longitudinal scan of the nondominant anterior arm muscles in the 24-h interval. The results indicate that there is variable reliability of the measurements depending on the muscle, time frame, body side, and scan orientation. Consequently, the choice of these parameters can affect the validity of the measurements. Further investigation on a larger scale is required to establish the preferred parameters for each anatomical site.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MRR.0000000000000390DOI Listing

Publication Analysis

Top Keywords

muscle thickness
12
body side
8
scan orientation
8
anterior arm
8
arm muscles
8
24-h interval
8
longitudinal scan
8
measurements
5
reliability muscle
4
thickness measurements
4

Similar Publications

Purpose: Photon counting detectors offer promising advancements in computed tomography (CT) imaging by enabling the quantification and three-dimensional imaging of contrast agents and tissue types through simultaneous multi-energy projections from broad X-ray spectra. However, the accuracy of these decomposition methods hinges on precise composite spectral attenuation values that one must reconstruct from spectral micro-CT. Errors in such estimations could be due to effects such as beam hardening, object scatter, or detector sensor-related spectral distortions such as fluorescence.

View Article and Find Full Text PDF

Although the connection between muscular strength and flatfoot condition is well-established, the impact of corrective exercises on these muscles remains inadequately explored. This study aimed to assess the impact of intrinsic- versus extrinsic-first corrective exercise programs on muscle morphometry and navicular drop in boys with flexible flatfoot. Twenty-five boys aged 10-12 with flexible flatfoot participated, undergoing a 12-week corrective exercise program, with a shift in focus at six weeks.

View Article and Find Full Text PDF

Pulmonary arterial hypertension (PAH) is a serious medical condition that causes a failure in the right heart. Two-pore channel 2 (TPC2) is upregulated in PAH, but its roles in PAH remain largely unknown. Our investigation aims at the mechanisms by which TPC2 regulates PAH development.

View Article and Find Full Text PDF

Morphological and molecular characterization of a Sarcocystis bovifelis-like sarcocyst in American beef.

Parasit Vectors

December 2024

United States Department of Agriculture, Agricultural Research Service, Beltsville Agricultural Research Centre, Animal Parasitic Diseases Laboratory, Beltsville, MD, 20705-2350, USA.

Background: Parasites in the apicomplexan genus Sarcocystis infect cattle worldwide. Assessing the economic importance of each such parasite species requires proper diagnosis. Sarcocystis cruzi, a thin-walled species, infects virtually all cattle.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the integrity of the repaired rotator cuff between 1 and 2 years postoperatively after arthroscopic rotator cuff repair (ARCR) using magnetic resonance imaging (MRI), investigate the factors affecting its change, and assess the association between the change and postoperative clinical outcomes.

Methods: Rotator cuff tear patients who underwent ARCR and were evaluated by MRI before surgery, and 1 and 2 years after ARCR with a minimum of 2-year follow-up were included in this study. Repair integrity was evaluated using Sugaya's classification, and according to the classification types IV and V were defined as re-tears.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!