A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dislocation after total hip arthroplasty: does head size really matter? | LitMetric

Introduction: Recent advances in polyethylene and ceramic technologies has allowed us to use larger sized heads without compromising the wear properties of a total hip arthroplasty (THA). 1 benefit of this change has been proposed to be a lower incidence of dislocation.

Methods: We retrospectively evaluated the dislocation rate in 913 THAs performed using the same standardised surgical technique employed by a single team of surgeons at our institution between 1995 and 2015. Patients were assigned to 2 groups: small (⩽28 mm), large diameter heads (⩾36 mm and larger). The cup position was measured and plotted to determine its status according to the Lewinnek's safe zone (15° ± 10° for anteversion, 40° ± 10° for inclination).

Results: 16 of the 472 small heads dislocated (3.4%) while 5 of the 441 in large head group (1.1%) ( = 0.04). In all of the large head patients that dislocated the cup position was in the safe range of Lewinnek. However, in the large head group only 64.5% of the cups were in the safe zone.

Conclusions: By changing the head size to 36 mm, we were able to decrease the dislocation rate significantly. Errors of cup positioning according to Lewinnek became oblivious when using large heads. In our opinion, using large heads in THA makes a difference in terms of dislocation.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1120700019898404DOI Listing

Publication Analysis

Top Keywords

large head
12
total hip
8
hip arthroplasty
8
head size
8
dislocation rate
8
cup position
8
head group
8
large heads
8
large
6
head
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!