Purpose: The proliferation marker Ki67 has prognostic and predictive values in breast cancer, and the cutoff of the Ki67 label index (LI) is a key index for chemotherapy. However, poor interobserver consistency in Ki67 assessment has limited the clinical use of Ki67, especially in luminal cancers. Here, we reported a modified Ki67 assessment method, size-set semiautomatic counting (SSSAC) and investigated its interobserver reproducibility.

Methods: One hundred invasive breast cancer tissues were set immunostained for Ki67 in one laboratory, scanned as digital slides, and sent to 41 pathologists at the laboratories of 16 hospitals for Ki67 LI assessment using size-set semiautomatic counting (SSSAC), size-set visual assessment (SSVA) and size-set digital image analysis (SSDIA) with a specific image viewing software (Aperio Image Scope, Leica, Germany). The intraclass correlation coefficient (ICC) and Bland-Altman plot were used to evaluate interobserver reproducibility. The Wilcoxon signed-rank test was used to analyze the difference in the Ki67 values assessed by SSSAC and SSDIA.

Results: SSSAC demonstrated better interobserver reproducibility (ICC = 0.942) than SSVA (ICC = 0.802). The interobserver reproducibility was better in Ki67 homogeneously stained slides and centralized hot-spot slides than in scattered hot-spot slides. The Ki67 value assessed with SSSAC was obviously higher than that assessed with SSDIA (negative ranks (SSDIA < SSSAC): N = 80, sum of ranks = 4274.50; positive ranks (SSDIA > SSSAC): N = 17, sum of ranks = 478.50; Z = -6.837; P < 0.001).

Conclusion: SSSAC shows satisfactory interobserver reproducibility in the Ki67 assessment of breast cancer and may be a candidate standard method for Ki67 LI assessment in breast cancer and other malignancies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7375572PMC
http://dx.doi.org/10.1016/j.breast.2019.12.009DOI Listing

Publication Analysis

Top Keywords

interobserver reproducibility
16
ki67 assessment
16
size-set semiautomatic
12
semiautomatic counting
12
breast cancer
12
ki67
11
counting sssac
8
assessed sssac
8
hot-spot slides
8
interobserver
6

Similar Publications

Background: The Bethesda System for Reporting Thyroid Cytology (TBSRTC) recommended for the interpretation of needle aspiration cytology of the thyroid, is the most widely used worldwide. Studies have shown that the disagreement between observers, especially in the Bethesda III and IV diagnostic categories, is not insignificant at 10%-40%. In the TBSRTC 2023 version, some definitions were removed and simplified, and molecular pathology was proposed as a complement to cytopathology.

View Article and Find Full Text PDF

Background: Diagnosing laryngopharyngeal reflux (LPR) is challenging due to overlapping symptoms. While proton pump inhibitors (PPIs) are commonly prescribed, reliable predictors of their responsiveness are unclear. Reflux monitoring technologies like dual potential of hydrogen (pH) sensors and multichannel intraluminal impedance-pH (MII-pH) could improve diagnosis.

View Article and Find Full Text PDF

BK Polyomavirus nephropathy (PVN) with definitive diagnosis on biopsy, presents incidentally or with varying degrees of graft dysfunction. Banff working group on PVN has proposed a novel scoring system in renal biopsies, to identify patients with higher risk of graft failure. In this study, we attempted to validate the Banff scoring system at index biopsies and correlate with a novel index score, plasma BK-virus load and graft outcome.

View Article and Find Full Text PDF

Background: The Peritoneal Cancer Index (PCI), calculated intraoperatively, has previously yielded mixed results when correlated with computed tomography. This study aimed to quantify variation in this scoring method comparing radiologists' and surgeons' radiologic PCI (rPCI) assessment.

Methods: The rPCI of 104 patients treated at a single institution for peritoneal carcinomatosis was calculated by an abdominal radiologist and a surgeon.

View Article and Find Full Text PDF

Introduction: Patellar fractures are rare at 1% incidence of all fractures. However, they can cause significant functional impairments due to the patella's role in knee joint extension. Current scoring systems lack objectivity in assessing patellar healing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!