Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Rotating hinge knee prostheses (with or without distal femoral replacement) are indicated in cases of unreconstructible bony or soft tissue compromise. Despite their versatility, these implants have demonstrated high rates of mechanical failure. We aimed to review clinical outcomes of a novel hinged knee arthroplasty system.
Methods: We reviewed all cases in a prospective database of hinged total knee arthroplasty (with and without distal femoral arthroplasty) involving a single manufacturer's implant system at a large tertiary-level academic health sciences center. We collected reasons for surgery, implant survivorship, reasons for revision, and clinical outcomes (Short Form 12, Western Ontario and McMaster Universities Osteoarthritis Index, and Knee Society Scores).
Results: Seventy-six cases of hinged knee implants using the knee system under investigation were performed (39 hinged total knee and 37 distal femoral replacements) between 2011 and 2018, inclusive. Indications for surgery varied, with second-stage reimplantation most common for rotating hinge and fracture most common for distal femoral arthroplasty. There were 6 revisions in the rotating hinge group (none for aseptic loosening) and 5 in the distal femoral arthroplasty group (1 for aseptic loosening). Average follow-up was 2.89 ± 2.09 years. Postoperative Short Form 12 (Physical Component), Western Ontario and McMaster Universities Osteoarthritis Index, and Knee Society Scores were 30.12 ± 10.17, 55.90 ± 21.51, and 115.62 ± 45.20, respectively.
Conclusion: This novel hinged knee system is a highly durable option for complex and revision knee arthroplasty. Early failures tend to be secondary to infection. We observed only a single case of aseptic loosening. Although these early results are encouraging, ongoing follow-up is required to determine long-term prognosis in patients receiving this implant.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2019.12.024 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!