Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Nitric oxide (NO) is a vasodilator and platelet aggregation inhibitor. In patients with pulmonary hypertension, inhalation of NO is used as a therapeutic option. It has been proposed that nitrite (NO ) is a constitute intravascular storage and delivery source of NO, a potent cardioprotective-signaling molecule. The administration of NO could have therapeutic effects in conditions where the oxygen-dependent enzymatic production of NO is compromised (i.e., ischemia). Thus, if NO could be supplied by an intravenous infusion fluid, it would be an easier method than by inhalation or delivery to the blood vessels by the blood stream. We produced 2 types of solutions, i.e., a nitrogen gas injected solution (control solution) and NO gas injected solution (experimental solution). NO was measured by the Microplate Photometer (MultiSkan FC, Thermo Fisher Scientific K.K., Tokyo, Japan) with a 540-nm wavelength and NO assay kit (Quantichrom™ Nitric Oxide Assay Kit, BioAssay Systems, Hayward, CA, USA). Gas profiles were measured by the EG6+ (Abbott Japan Co., Ltd., Osaka, Japan) with an i-STAT system (300F, Abbott Japan Co., Ltd.). Comparisons of gas profiles and measured NO concentrations in vitro and ex vivo are shown between the control and experimental solutions. Since NO is oxidized to NO and nitrate (NO ), it is common practice to quantitate total NO /NO as a measure of the NO level. We used the assay that was designed to accurately measure NO production following reduction of NO to NO using the Griess method. The data in this document describe production of an infusion fluid that contains NO without any special devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6938946 | PMC |
http://dx.doi.org/10.1016/j.dib.2019.105011 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!