Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Study Design: Prospective cohort study.
Objective: The aim of this study was to compare clinical outcomes, radiographic changes, and complications of cervical expansive open-door laminoplasty(EOLP)for cervical multilevel myelopathy, using either 3 or 5 titanium miniplates.
Summary Of Background Data: Cervical EOLP is a common and effective operation for cervical myelopathy. Standard procedures utilise either 3 or 5 titanium miniplates; however, no definite conclusion has been given yet on the relationship between clinical outcomes and the quantity of titanium miniplates.
Method: We performed a prospective study of 92 patients who underwent EOLP with either 3 (n = 34) or 5 (n = 58) titanium miniplates at our institution from March 2012 to June 2016. Clinical and radiologic outcomes and complications were compared.
Result: Compared with the 5 titanium miniplates group, the 3 titanium miniplates group had shorter operation times and less blood loss (P < 0.05) and needed fewer costs (P < 0.01) during index hospitalisation. The preoperative cervical curvature angle decreased in both groups and revealed no significant differences. There was no significant difference between the two groups in the Japanese Orthopedic Association (JOA) score, JOA recovery rate, loss of range of motion (ROM), anteroposterior diameter (APD), or spinal canal complications (P > 0.05).
Conclusion: Cervical EOLP using 3 titanium miniplates is associated with shorter operation times, less blood loss, and lower operation costs compared with using 5 titanium miniplates.
The Translational Potential Of This Article: Expansive open-door laminoplasty (EOLP) is an effective procedure for treating multilevel cervical spondylotic myelopathy. The present study indicated that 3 titanium miniplates could achieve similar clinical outcomes but with shorter operation times, less blood loss and operation costs compared with 5 titanium miniplates. These findings may provide some references for clinical applications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6939103 | PMC |
http://dx.doi.org/10.1016/j.jot.2019.10.008 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!