Purpose: Long-term results of total hip arthroplasty (THA) using highly cross-linked polyethylene (HXLPE) and metal femoral head with more than 10 years of follow-up have already been reported. However, most studies included results with a head size of 28 mm that could affect wear rates. The aim of this study was to evaluate the results of 36-mm metallic femoral heads on first-generation HXLPE in patients less than 60 years of age with a minimum follow-up of 10 years.
Methods: Retrospective analysis included 54 cases from 47 patients. The mean age at the time of surgery was 47.22 years and the mean follow-up period was 131.04 months. Porous-coated cementless acetabular cups (Trilolgy®; Zimmer Inc., Warsaw, Indiana, USA) and HXLPE acetabular liners (Longevity®; Zimmer Inc.) were used for all cases. Acetabular cup abduction angles, anteversion angles, and wear rates of liner were measured using polyWare pro 3D distal version 5.10.
Results: The average modified Harris hip score at the final follow-up was 88.48 (range 80-96). Average Merle d'Aubigne and Postel score was 15.57 (range 14-18). There was no acetabular cup or femoral stem failing due to aseptic loosening. The average steady-state wear rate determined using radiographs taken at 1 year postoperatively and at the latest follow-up was 0.053 ± 0.025 mm/year. There were no statistically significant differences in liner wear rate with respect to age, variety of the femoral stem, or liner thickness.
Conclusion: Results of THA with 36-mm metallic femoral heads on first-generation HXLPE in patients less than 60 years of age were satisfactory.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/2309499019896448 | DOI Listing |
J Orthop Physician Assist
January 2024
Department of Biomedical Sciences, West Liberty University, West Liberty, WV, United States of America.
Legg-Calvé-Perthes Disease (LCPD) is a condition marked by temporary blood flow disruption to the proximal femur, commonly afflicting children aged 15 and younger. The etiology of the disease is often idiopathic and involves the development of avascular necrosis of the femoral head, subsequently leading to bone weakening and deformity. Obesity exacerbates LCPD, correlating with delayed diagnosis, increased disease severity, and bilateral involvement.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Department of Orthopedics and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China.
Background: Osteonecrosis of the femoral head (ONFH) is a challenging condition, primarily affecting young and middle-aged individuals, which results in hip dysfunction and, ultimately, femoral head collapse. However, the comparative effectiveness of joint-preserving procedures, particularly in the early stages of ONFH (ARCO stage I or II), remains inconclusive. This study aims to evaluate the efficacy of a novel technique called small-diameter core decompression (CD) combined with platelet-rich plasma (PRP), for the treatment of early-stage ONFH.
View Article and Find Full Text PDFMol Med Rep
March 2025
Department of Orthopedics, People's Hospital of Zhengzhou University, Zhengzhou, Henan 450003, P.R. China.
Aseptic loosening (AL) of artificial hip joints is the most common complication following hip replacement surgery. A total of eight patients diagnosed with AL following total hip arthroplasty (THA) undergoing total hip replacement and eight control patients diagnosed with avascular necrosis of femoral head (ANFH) or femoral neck fracture undergoing THA were enrolled. The samples of the AL group were from synovial tissue surrounding the lining/head/neck of the prosthesis, and the samples of the control group were from the synovium in the joint cavity.
View Article and Find Full Text PDFBone Joint J
January 2025
Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
J Orthop Surg Res
December 2024
Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.
Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).
Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!